8.2 Automatic Air-conditioning
8.2.1 Specifications
8.2.1.1 Fastener Tightening Specifications
Applications
Model
Specifications
Metric (Nm)
US English (lb-ft)
Condenser Cylindrical Side Nut
M8
10-12
7.4-8.9
Air-conditioning Retaining Screw
ST6.3 × 19
5-7
3.7-5.2
Air-conditioning Retaining Nut
M6
5-7
3.7-5.2
Air-conditioning Retaining Bolts
M6 × 20
8-10
5.9-7.4
Air-conditioning Inlet Pipe Nut
M6
5-7
3.7-5.2
Compressor Retaining Bolts
M8 × 1.25 × 80
23-28
17.0-20.7
Compressor Suction Hose Retaining Bolts
M6 × 30
10-12
7.4-8.9
Compressor Discharge Hose Retaining
Bolts
M6 × 30
10-12
7.4-8.9
High-pressure Pipe Fittings
M19
27-29
19.9-21.4
Low Pressure Pipe Fittings
M24
37-39
27.3-28.8
Air-conditioning High-pressure Pipe Bracket
Bolts
M6 × 12
5-7
3.7-5.2
Air-conditioning Control Panel Retaining
Bolts
M5 × 16
5-7
3.7-5.2
Suction Hose Bracket Bolts
M6
5-7
3.7-5.2
Condenser Upper Pipe
M6 × 25
9-11
6.7-8.1
Condenser Lower Pipe
M6 × 25
9-11
6.7-8.1
Expansion Valve Retaining Bolts
M8 × 20
16-20
11.8-14.8
Blower Speed Control Module Retaining
Screws
ST4.8 × 16
2-4
1.5-3.0
8.2.1.2 Cooling System Parameters
Applications
Parameters
Compressor
Displacement (ml/r)
167
Model
CHD115
Electromagnetic Clutch Power Consumption
(W)
45
Blower
Maximum Air Volume (m
3
/ h)
≥480
Air Volume Control
7-speed Automatic
Heating, Ventilation and A/C System
Automatic Air-conditioning