Working Platform
Assembly and Operating Manual
Page 13 of 52
BL 061 U Edition 06.2007
5
Technical data
Type:
GEDA AB 450
230V/AC drive
unit
GEDA AB 450
400V/AC drive
unit
GEDA AB 650
400V/AC
drive
unit
-
Winch traction force
4500N
4,500N
6,500N
-
Voltage
230V/50Hz
400V/50Hz
-
Current input (per winch)
7,5A
3.0A
-
Max. starting current (per winch)
approx. 30A
approx. 14.5A
-
Output (per winch)
1,3kW
1.4kW
-
Maximum assembly height
55m
-
Control voltage
48V
-
Motor speed
2800 1/min.
-
Hoisting speed
8 m/min
-
Release speed of cable breakage safeguard
20m/min
-
Duty cycle (DC)
60%
-
Protective system
IP 54
-
Noise emission values
(The measuring uncertainty constant is 4 dB (A))
L
PA
< 85 dB (A)
-
Dynamic pressure:
During assembly and when in operation
-
Out of operation
q = 100N/m² (= 45km/h
)
platform on ground
-
Basis for calculation
EN 1808
-
Roof extension
front projection (rope suspension)
rear projection (ballast weights)
0.6 – 2.0 m
2.4m (2.6m) – 4.4m
-
Rope:
according to EN 12385-4;
- Nominal diameter
8.3mm
- Measured breaking force
51.00kN