Assembly
GEDA
®
3700 Z/ZP
Assembly Instructions
Page 58 of 60
ML034 GB 2017 / 11
6.12
Check after assembly and before each operation
•
Check to ensure that
o
the specified maintenance work and inspection procedures have
been carried out.
o
the gear rack is adequately greased.
(Check/set the lubricating pump selector switch.)
o
there is no oil leakage at the geared motor.
o
the supply cable has an adequate cross section.
o
the motor rotation direction agrees with the
UP
and
DOWN
buttons of
the control locations and that the
EMERGENCY STOP
button
interrupts travel.
o
the length of trailing cable is sufficient for the assembly height.
o
information plates are present and legible (refer to Appendix A)
o
The danger zone at the lower loading point is cordoned off and
marked or a ground base enclosure is fitted.
o
The loading door can only be opened when the platform is stationary
on the ground (stopped by the
DOWN
limit switch).
o
a landing level safety gate can only be opened when the platform has
been unlocked by the open barrier with unloading ramp.
•
Carry out a test run with
loaded
platform and check whether the motor
brake functions correctly.
•
Check to make sure that the platform control, ground control (manual)
and (if present) electric module on the landing level safety gate function
correctly. (Refer to the instruction manual).
•
There must be no sign of damage to the trailing cable, mains supply line
and control lines.
•
Carry out a drop test to check the function of the safety gear.
(Refer to the maintenance manual).
6.12.1
Train authorized personnel
•
Instruct the platform operator, give the handover report and
documentation to an authorised person (platform operator) (record
name and obtain signature of the trained persons in the handover
report).
•
Transfer the key for the platform control to the authorised and instructed
person.
Check the 3700 Z/ZP in accordance with national regulations after
assembly and before initial commissioning, as well as after each
assembly at a new site.