Assembly
GEDA
®
3700 Z/ZP
Assembly Instructions
Page 46 of 60
ML034 GB 2017 / 11
Platform A
Anchoring conditions / forces
Load capacity
3700 kg
Anchoring distance
G
12 m
Anchoring distance
A
≥
1.2 m
Variable
Distance mast (centre) to the wall
B
1.7 m - 1.8 m
fixed -
>
minimal wall
distance
Anchoring distance
A
≥
1.7 m
Variable
Distance mast (centre) to the wall
B
2.7 m - 2.8 m
fixed -
>
maximal wall
distance
Wind region A / B
EN 16719
Wind speed 141 km/h
Wind load / dynamic
pressure 960 N/m²
Tie force
Fx
1
[N]
Fy
1
[N]
Fx
2
[N]
Fy
2
[N]
Fx
3
[N]
Fy
3
[N]
Fx
4
[N]
Fy
4
[N]
All anchor points
without
mast
projection
512
5495 3450 5495
512
5495 3450 5495
Uppermost anchor
at
*M = 7.5 m
950 14800 8581 14783 950 14800 8581 14783
Wind region C
EN 16719
Wind speed 165 km/h
Wind load / dynamic
pressure 1306 N/m²
Tie force
Fx
1
[N]
Fy
1
[N]
Fx
2
[N]
Fy
2
[N]
Fx
3
[N]
Fy
3
[N]
Fx
4
[N]
Fy
4
[N]
All anchor points
without
mast
projection
681
7463 4122 7463
681
7463 4122 7463
Uppermost anchor
at
*M = 7.5 m
1275 19860 11635 20054 1275 19860 11635 20054
Wind region D
EN 16719
Wind speed 188 km/h
Wind load / dynamic
pressure 1706 N/m²
Tie force
Fx
1
[N]
Fy
1
[N]
Fx
2
[N]
Fy
2
[N]
Fx
3
[N]
Fy
3
[N]
Fx
4
[N]
Fy
4
[N]
All anchor points
without
mast
projection
876
9736 5393 9736
876
9736 5393 9736
Uppermost anchor
at
*M = 7.5 m
1650 25895 15154 26135 1650 25895 15154 26135
Wind region E
EN 16719
Wind speed 212 km/h
Wind load / dynamic
pressure 2159 N/m²
Tie force
Fx
1
[N]
Fy
1
[N]
Fx
2
[N]
Fy
2
[N]
Fx
3
[N]
Fy
3
[N]
Fx
4
[N]
Fy
4
[N]
All anchor points
without
mast
projection
1166 13145 7286 13145 1166 13145 7286 13145
Uppermost anchor
at
*M = 7.5 m
2206 34919 20407 35228 2206 34919 20407 35228
At dimension
Z
<
7.5 m,
the lowest anchoring forces are required.