Assembly
GEDA
®
3700 Z/ZP
Assembly Instructions
Page 44 of 60
ML034 GB 2017 / 11
6.8.3
Tie forces
The stated values apply:
•
per tie point
•
for the assembly geometry shown
If the assembly geometry is changed, the corresponding values must be
requested. The stated values do not include any safety factors. The wind
loads used to determine the tie forces refer to the European wind regions
according to EN 12158.
The wind load in other regions must be calculated according to ISO 4302
and the next value up in the table below must be applied.
European wind map
Assembly
height H[m]
Wind forces for geographical regions [N/m²]
A/B
C
D
E
0<H
≤
10
544
741
968
1225
10<H
≤
20
627
853
1114
1410
20<H
≤
50
757
1031
1347
1704
50<H
≤
100
879
1196
1562
1977
100<H
≤
150
960
1306
1706
2159
150<H
≤
200
1023
1393
1819
2303