5.3.4
Overload warning device has triggered
The platform is equipped with an overload warning device which
prevents the platform from being operated when it is overloaded.
If the platform is overloaded, the red control light (1) on the platform
switch box illuminates.
Reduce the load weight on the platform
until the red control light (1) goes out.
- Only then is travel possible.
5.3.5
Safety gear has triggered
The transport platform is equipped with an overspeed safety device that
halts the platform if overspeed is detected. Further travel is not possible
once the safety gear has been triggered.
WARNING
Danger to life
All persons must exit the platform
Determine why the safety gear has engaged, secure
the platform and repair the damage before releasing the
safety gear!
The safety gear must only be released by a competent
person specifically appointed by the operating company
who, due to his/her training, knowledge and practical
experience, is able to evaluate the risks and assess the
safe condition of the safety gear.
1