18.5
Checking for wear
18.5.1
Drive pinion
Number of teeth = 21
Module m = 6
Wear limit
Dimension
X min.
Dimension
X normal
27,6 mm
28,3 mm
Measure dimension X on each tooth
X
18.5.2
Gear rack
Wear limit
(A) min.
(A) new
68,5 mm
69,6 mm
Gauging pin: (
D
) = 12 mm (+0.0 / -0.11 mm)
(
B
) = 65,2
A
Ø D
B
Check that all gear racks are positioned securely. If necessary tighten gear racks with
60 Nm. (8 mm Allen key)
WARNING
Danger of injury from components failing
Parts must be replaced immediately if the specified wear limits
are exceeded. Machine operation is prohibited until the parts
have been replaced. All parts must also be checked for damage
(deformation, cracks, cavities, etc.).