GEDA
®
1500 Z / ZP
Page 71 of 114
Rev.: 004
BL 076 GB
Translation of the original operating manual
2011 / 03
Manual control
Dead man's control
Selector switch
(2) to position “
I
”
Ascent
Press the
UP
(3) button.
The platform only moves as long as the
UP
(3) button is pressed.
The platform
overruns
the landing level limit
switch approach bar and is stopped by the
UP
limit switch.
Descent
Press the
DOWN
(4) button.
The platform only moves as long as the
DOWN
(4) button is pressed.
The platform descend and stops automatically approx. 2 m above the
ground. It triggers a warning tone for approx. 3 seconds. During this time
the control function is interrupted.
WARNING
The operator may only continue the descent after he has ensured that the
travel path to the ground station is free.
Press the
DOWN
(3) button again or hold it; after the warning tone the
platform moves down to the ground and is stopped by the limit switch.
In an emergency the platform is stopped by pressing the
EMERGENCY STOP
button (1).
2
1
3
4