GEDA
®
1500 Z / ZP
Page 45 of 114
Rev.: 004
BL 076 GB
Translation of the original operating manual
2011 / 03
7.7
Supplementary
safety instructions
Servicing/repairs/maintenance
All relevant people (e.g. operating personnel, superiors) must be
informed about how to carry out the work before starting work.
Before carrying out servicing/repair work, the machine must be
turned off at the main switch and secured against unauthorised
switch-on (e.g. with a padlock).
Work on the platform may only be carried out when it is at the
ground station. If the platform needs to be raised, it must be
secured by appropriate supports.
Work on electric/live components may only be carried out by
qualified electrical personnel.
Affected electrical parts must be de-energised (disconnect the
mains voltage upstream from the main switch).
Do not touch sockets, cables or electrical components with wet or
damp hands.
Dry or appropriately cover wet, slippery or sharp surfaces. There
must be no potential for hazards.
All work on electrical components may only be carried out with
insulated tools.
Connect the machine only at a building site main cabinet according
to IEC 60439-4:2004.
Never bypass fuses. Only ever replace fuses with fuses of the same
type.
Use appropriate measures to ensure that mobile/loosened parts are
blocked during work and that no limbs can become trapped by
unintentional movements.
Use appropriate measures to ensure that dismantled parts do not
fall down.
Loss of balance from handling heavy parts/tools. Only raise heavy
parts/tools with another person or appropriate lifting equipment.
Only use new parts according to their intended use and within the
specifications of their technical data.
Test that the parts are functioning correctly after any work. Make
sure that no hazards will arise from the machine being started up.
Only carry out welding, burning and grinding work on the machine
after consultation and approval from GEDA.