GEDA
®
1500 Z / ZP
Page 30 of 114
Rev.: 004
BL 076 GB
Translation of the original operating manual
2011 / 03
3.9.9
Tests
The following tests have been carried out before delivery:
Dynamic test with the safety gear with 1.25 of the maximum load
capacity using a drop test.
Electrical tests according to EN 60204.
Function
tests.
3.9.10
Operating and environmental conditions
The machine may only be operated if the following operating and
environmental conditions are maintained:
Temperature range
minimum - 20 °C
m40 °C
Wind speed
Operation/maintenance/servicing maximum 72
km/h
Assembly
maximum
45 km/h
No bad weather with a risk of lightning. Observe the height-specific
changes to the wind speed. It may be necessary to cease/prohibit
operation of the machine under extreme weather conditions, even if the
operating and environmental conditions fall within the bounds of those
stated. For example if a sand/snow storm occurs. The operating company
must provide appropriate regulations for these matters.
Atmosphere
The atmospheric composition on-site must be suitable for people to remain
in the area for longer periods. In particular, any reduction in the oxygen
content due to displacement or consumption must be prevented. The legal
limit values for pollutant concentrations/aerosols and dust at the workplace
must not be exceeded.
Material transport
Material transport must not lead to a concentration of aggressive/corrosive
materials. If this cannot be ruled out with certainty, then the corrosion
protection and/or the functional reliability of the electrical components must
be inspected at regular intervals and if necessary replaced.
The generation/collection of (explosive) micro-dust
must be prevented/removed immediately.
Assembly site elevation
Up to max. 1000m above sea level.