GEDA
®
1500 Z / ZP
Page 103 of 114
Rev.: 004
BL 076 GB
Translation of the original operating manual
2011 / 03
18.6.2
Drop test successful
Press the
UP
(1) button.
The platform moves out of the drop position.
Turn the
turn
key (2) shortly (max. 1 sec).
The platform descends.
Repeat the process until the platform has descended.
Disconnect the drop test control.
Insert the dummy plug.
Check the
safety gear for damage.
18.6.3
Drop test not
successful
Turn the
turn
key (2) shortly (max. 1 sec).
The platform descends.
Repeat the process until the platform has descended.
Switch the machine off at the main switch and secure is from being
switched back on.
Press the
UP
button (1) until the platform is
approx. 6 m high.
Turn the
turnkey
(2) to the right.
The brake opens and the platform moves
downwards.
The safety gear must stop the platform after
approx. 2–3 m
If the platform does not stop:
Release the turnkey (2).
WARNING
Danger of injury
Immediately replace the safety gear. Until then machine
operation is prohibited.
2
1