GEDA
®
1500 Z / ZP
Page 61 of 114
Rev.: 004
BL 076 GB
Translation of the original operating manual
2011 / 03
10.6
Safety stop
When the safety stop is activated, the platform stops approx.. 2 m above
the ground. A warning tone sounds for approx. 3 seconds. Subsequently,
the movement can be continued to the ground station by pressing the
button AB.
WARNING:
Before travelling further it is vital to ensure that nobody remains in the
hazard area beneath the platform.
10.7
Safety gear
Protects the platform against an un-braked fall, e.g. in the event of gear
damage.
10.8
EMERGENCY limit switches
The emergency limit switch stops the platform at the top or bottom end
position. This prevents, for example, the platform moving past the top end
position.
10.9
Locks to prevent unauthorised use
Areas with limited access (switch cabinets etc.) are secured using locks.
HAZARD
Life-threatening hazard
through crushing.
Never stand underneath the platform/in the
hazard area during operation.
Turn the master switch off and secure against
being switched back on while working in the
hazard area.