1- Connect all outputs & keypads
3- Select spa configuration (if prompt on startup)
3
At first startup the keypad display
will show
Lx
or
LLx,
where « x »
representing the config. number. Some
spa packs come with a pre-selected
config. and you may skip this step if
your system automatically starts up
1
.
Use the
Up/Down
key to choose the
new low level configuration number.
Press the
Program
2
key to confirm
the selection.
2
1
2- Connect the main power
Light outputs
(P34 always on, P35 relay controlled)
Main power
entry connection
Heater
connections
Heater
Bonding lugs
A1
A2
A3
A4
C3
C2
C1
H
L
G
C
A4
A3
A2
A1
C1 - Main keypad connector
CO - Communication links (2 ports)
in.touch, in.stik, Aux keypad in.k112,
Swim Spa com. cable, etc.
For 240 V (4 wires)
Connect wiring of the electrical
service box GFCI. Neutral wire is
mandatory.
For 120 V (*3 wires)
* If connected to a 3 wire system,
any 240 V components will not
work.
For 240 V (4 wires)
L2
N
L1
G
For 120 V (*3 wires)
WARNING!
All connections must be made by a qualified electrician in accordance with the national electrical code and any state, provincial or local electrical code in
effect at the time of the installation. This product must always be connected to circuit protected by a Ground Fault Circuit Interrupter (GFCI).
2.a- Electrical wiring
Heater voltage
Verify BROWN common wire
connection to tab:
P9 - 240 V (default)
P10 - 120 V
Pumps & accessories voltage
Verify each WHITE common wire
connection to tab:
N - 120 V (default)
L2 - 240 V pump/acc.
P9
2.b- Heater & pump/accessories voltage
P10
N
L1
G
G C
H
L
C1
C2
C3
AMP ports (A0 to A4,
and C1 to C3) for pumps
& accessories. Function
varies per configuration
(see next page).
A0
H
L
G
C
Optional
floating connector
(Part #9920-401346)
1
Note: To re-enter the low level
selection menu, hold the Pump 1
key for 30 seconds.
Note:
For the
Color keypad series
,
select
Settings menu
, go into
Electrical config
and choose the
appropriate Low level.
2
Note: If the keypad does not have
a Program or Filter key, use the
Light key instead.
For more information, see our
website: www.geckoalliance.com
4- Select breaker current
GFCI
b
60 A
48 A
50 A
40 A
40 A
32 A
30 A
24 A
20 A
16 A
15 A
12 A
3
2
1
(10 to 20 A dedicated to 120 V)
Press and hold the
Program
key
for 20 seconds until you access the
breaker setting menu.
Note:
For the
Color keypad series
,
select
Settings menu
, go into
Electri-
cal config
and choose Input current.
Use the
Up/Down
key to select the
desired value. Then press the
Program
key to confirm the selection.
Note
: If the keypad does not have the
Program
or
Filter
key, use the
Light
key instead.
The values displayed by the system
correspond to 80% of the maximum
amperage capacity of the GFCI.
For more information, see our
website: www.geckoalliance.com
Quick Start Card
in.yt-7
™
North American version