background image

In normal mode (in which the blower speed is constant), 

these keys allow the user to change the blower’s speed.

In wave or pulse mode, these keys allow the user to set 

the maximum blower's speed.

+ and - keys

Quick Reference Card

AIR.WAV-DTH

120-P-H600-GE1

User Instructions & Installation

The 

On/Off

 key is used to turn the blower on or off. 

When the blower is started, it will run for 20 minutes. 

The indicator light in the upper right corner of the key 

will be on to indicate that the blower is running.

On/Off key

Pressing the 

Pulse

 key while the blower is running makes 

the blower speed rapidly change from the minimum to a 

user-defined maximum. The "On/Off" indicator light will 

flash to indicate pulse mode. Pressing the 

Pulse

 key a 

second time will turn the blower back to normal mode, 

at constant speed.

Pulse key

Fifteen minutes after the system has shut off, the blower will 

start up again for a one-minute purge cycle allowing the 

system piping to dry. The indicator light will flash during  

the 15-minute pause.

Automatic purge

It is possible to program a 1-minute purge that will be 

repeated every day at the same time. To enable the daily 

purge, press and hold the + key for 5 seconds. The "On/

Off" indicator light will flash twice as a confirmation. 

To disable the programmable daily purge, press and hold 

the + key for 5 seconds again.

Programmable daily purge

Pressing the 

Wave

 key while the blower is running makes 

the blower speed gradually change from the minimum to a 

user-defined maximum. The "On/Off" indicator light’s inten-

sity changes smoothly to indicate wave mode. Pressing the 

Wave

 key a second time will turn the blower back to 

normal mode, at constant speed.

Wave key

To be read prior to installation!

Manufacturer warranty applies only if proper installation was performed. 

Reviews: