37
Maintenance
Setting the Proximity Switches
2.
Secure the proximity switch (15) using a hex. nut (15.1).
After securing the proximity switch (15), there must be a gap of 1 to 1.5mm between
areas (B) and (C) on the screw (19). If the gap is smaller or larger than 1 to 1.5mm,
the screw (19) must be adjusted.
Done
Vacuum Valve with Lifting Actuator Type V...E
IMPORTANT NOTE
Sensitive parts
The front of the proximity switch mounting can be damaged when the proximity switch is
fitted.
Pay attention when screwing in the proximity switch (15) that the piston (11) of the
lifting actuator is not deformed.
Carry out the following steps:
1.
Screw in the proximity switch (15) as far as it will go (A).