Carry out the following steps:
1.
Position the valve plates (65) incl. the flat seal on the pneumatic block (8) at
positions Y2 and Y3 with the groove (65.22) facing upwards.
2.
Tighten the screws (66).
®
Done
Hint!
When using the pneumatic block (8), the 2 valve plates (65) must be
fitted so that the groove (65.22) is pointing upwards. The screws (66)
are located in the lower mounting holes.
On ASEPTOMAG valves, a special type of pneumatic block must be
used! Tighten the screws (66) to a max. torque of 1 Nm.
10.5
Maintenance
10.5.1 Replacing the Seals on the Base
On VARIVENT actuators with a vent hole in the actuator cover the control top
must be fitted without O-ring (54)!
Fig.37
Carry out the following steps:
1.
Remove the O-rings (31, 54) and replace.
®
Done
10.5.2 Maintenance of Sound Absorber, Filter, Non-Return Valve and Exhaust Air Throttle
Maintenance
Maintenance
430BAL010747EN_3
52
24.07.2020