![GEA T.VIS P-15 Operating Instruction Download Page 42](http://html1.mh-extra.com/html/gea/t-vis-p-15/t-vis-p-15_operating-instruction_3967218042.webp)
8.2
Operating Overview
Tolerance setting
0.3mm
-
m
in
u
s
b
u
tt
o
n
o
r
w
a
it
3
0
s
0.7 mm (for seat valves)
1.0 mm
2.0mm (for butterfly valves)
Tol. 1
Tol. 2
Tol. 3
Tol. 4
Deadband
<1%
<2%
m
in
u
s
b
u
tt
o
n
o
r
w
a
it
3
0
s
+
<3%
Programming mode
red permanent (SETUP active)
-
+
press both buttons
for 3 to 7 s
Störung detektiert
+
+
Default standard
3x red flashing/pause
First commissioning (not programmed;
(push buttons automatically locked after SETUP)
Note:
xxx
(bold and underlined) = standard settings
+
+
+
+
+
Control characteristic
linear
equal percentage
m
in
u
s
b
u
tt
o
n
o
r
w
a
it
3
0
s
Programming mode
Power up
Betriebsspannung Ein
Betriebsspannung Ein
-
+
press both buttons
for 3 to 7 s
Operation mode
yes
no
Recommissioning (programmed;
push buttons are locked 30s after power on)
Decision: New SETUP necessary?
Power up
Power up
Störung detektiert
Service
Dis-/Assembling
Power up
+
press and hold
Attention!
If power will be switched
off the valve disk will return
to the start position because
of spring force.
Activation of main stroke to
eliminate spring force.
To Fault Mode
exit by power off
Initial situation: T.VIS P-15 de-energised!
Mounting of valve insert
Programming mode
red permanent (SETUP active)
4x green 1x red
-
-
+
-
3x green, 1x red
2x green, 1x red
1x green, 1x red
2x blue, 1x red
1x blue, 1x red
-
-
-
-
-
yellow flashing
yellow permanent
green flashing
green permanent
Travel towards end
End position
Travel towards start
Start position
green flashing
green permanent
yellow flashing
yellow permanent
Valve status
Selected
color
green
or
yellow
blue flashing
blue permanent
not adjusted
adjusted
3x yellow, 1x red
red quick flashing
Error
no visualization
Assembly/Disassembly
Control operation
blue flashing
blue quick flash.
Manual mode
Manual mode
green quick flash.
yellow quick flash.
Valve status
2x yellow, 1x red
1x yellow, 1x red
Fig.26
Operation and control
Operating Overview
430BAL010747EN_3
42
24.07.2020
Summary of Contents for T.VIS P-15
Page 65: ...Appendix 430BAL010747EN_3 24 07 2020 65...
Page 66: ......