The control signals are given by the user's process control system or by
operating the solenoid valves manually. To do this, use a screwdriver to turn the
screw (S) from 0 to 1, see figure.
Fig.5
3.2.4
Control Top with Cap
Fig.6:
Control Top with Cap
According to protection class IP67 and/or 69k (EN 60529) the control top T.VIS
E-20 is suitable for use in this design and if the electrical and pneumatic
connections are installed correctly.
Observe the general instructions regarding ESD protection.
3.2.5
Safety Air Exhaust/Installation Position
To provide protection against excess pressure which can build up in the inside of
the control top, a vent plug (E2) is fitted in the base.
In operating mode, the exhaust air from the lifting actuators is discharged via this
vent plug. In the unlikely event of a damaged solenoid valve or in case of sealing
problems, pressure relief is ensured.
Description
Functional description