1.
Complete the T.VIS mounting base (198) with O-rings (29, 101) and a plain
bearing (202).
Fig.38
Fig.39
2.
Screw the adapter T.VIS E/SHO (139) into the actuator with open-end wrench
on wrench surface (139.1) and tighten.
3.
Screw the mounting base (198) into the actuator (A.3) via the adapter T.VIS
E/SHO (139) and tighten using a face spanner.
4.
Screw the switch bar T.VIS (1) into the adapters T.VIS E / SHO (139) and
tighten with open-end wrench at (1.2), torque 2 Nm.
5.
Place the control top over the T.VIS switch bar (1) and on the actuator.
6.
Tighten the clamp connection (15) with screws (39) at a torque of 1 Nm.
7.
Align the pneumatic and electrical connections in accordance with the valve
block configuration.
!
Internal air guiding is not possible on these valve types. Therefore connect
the air connection (Y1) on the control top and the connection (A.4.2) on the
actuator to the air hose (L).
8.
Perform commissioning, see Chapter 6, Page 41 and Chapter 7, Page 67.
®
Done.