7.5 Decommissioning
Close the shut-off valves on the compressor. Drain the refrigerant (it must not be discharged into the
environment) and dispose of it according to the regulations. When the compressor is depressurised,
undo the fastening screws of the shut-off valves. Remove the compressor using an appropriate hoist.
Dispose of the oil inside in accordance with the applicable national regulations.
7
|
Maintenance
7.4 Screw connections
7.3 Spare part recommendation
The following torques must be used when re-assembling the compressor.
EX-HG12P / ...
60 - 4S, 75 - 4 (S)
90 - 4 (S), 110 - 4 (S)
Designation
Item No.
Item No.
Set of valve plate
80361
80362
Set of gaskets
80359
Cylinder cover
M10
75 Nm
Bearing cover
M8
37 Nm
Oil drain screw
M8
34 Nm
Oil filler plug
1/4" NPTF
25 Nm
Flange connect., soldering supports for
shut-off valves
7/16"
M8
13 Nm
37 Nm
Plug
1/8" NPTF
25 Nm
Rotor
M8
37 Nm
INFO
Cylinder head / valve plate: starting from the middle, tighten screws
crosswise in at least two steps (torque 50/100 %).
Only use original GEA spare parts!
Information on available replacement parts can be obtained from the replacement parts list.
Further repair work can only be carried out at the factory.
INFO
I f system function must be guaranteed with certainty, we recom-
mend a standby compressor.