D
GB
F
E
7
96422-07.2018-DGbFEI
1
2
3
4
5
13
12
7
11
6
10
8
9
40/55
AX34567A045
C85E
44,8/25,9A
Δ
: 178A Y: 103A
GEA Bock GmbH
72636 Frickenhausen, Germany
HGX34e/255-4 S CO2
22,3
26,8
IP66
2
|
Product description
1
Type designation
2
Machine number
3
maximum operating current
4
Starting current (rotor blocked)
5
ND (LP): max. permissible operating
pressure
(g)
Low pressure side
HD (HP): max. permissible operating
pressure
(g)
High pressure side
50 Hz
60 Hz
6
Voltage, circuit, frequency
7
Nominal rotation speed
8 Displacement
9
Voltage, circuit, frequency
10 Nominal rotation speed
11 Displacement
12 Oil type filled at the factory
13 Terminal box protection type
}
}
Fig. 3
2.2 Name plate
(example)
Observe the limits of
application diagrams!
Electrical accessories can change
the IP protection class!
/
HG
4
3 e 255- 4
CO
2
X
S
2.3 Type key
(example)
¹
)
HG - Hermetic Gas-Cooled (suction gas-cooled)
²
)
X
- Ester oil charge
³
)
S
- More powerful motor
CO
2
version
Motor variant ³
)
Number of poles
Swept volume
e-series
Numbers of cylinders
Size
Oil charge ²
)