The motor is wired for direct start (YY) at the factory. For part winding start Y/YY the bridges must be
removed and the motor feed line connected according to the circuit diagram:
5
|
Electrical connection
INFO
When testing coils with resistance tester, please note that partial
winding 1 and partial winding 2 are wired internally in HG76e.
ATTENTION
Failure to do this results in opposed rotary fields and results in
damage to the motor. After the motor starts up via partial winding
1, partial winding 2 must be switched on after a maximum delay
of one second . Failure to comply can adversely affect the service
life of the motor.
400 V
Direktstart YY
Teilwicklungsstart Y/YY
1V1
1W1
1U1
2W1
2V1
2U1
L3
L2
L1
L3
L2
L1
L3
L2
L1
1V1
1W1
1U1
2W1
2V1
2U1
Direct start YY
Part winding start Y/YY