Programming
Detection parameters
2005-9015-009
01. August 2018
7.7
Detection parameters
The following parameters work together to set the sensitivity level of detection:
● Maximum load fluctuation (HP);
● Detection time (sec);
● Number of restarts.
Warning!
Risk of injury or death of animals!
A high ”MAX FLUCTUATION” setting combined to a high
”DETECTION TIME” reduces load detection sensitivity.
Keep these parameters set as low as possible.
Note!
During the first 15 seconds of each stroke, the control panel does not
perform detection since it only collects load fluctuation values.
It is strongly recommended to park the scraper(s) outside the free stall
area at a minimum distance of 56” (1.42m). See below.