Mounting, installation and connection
18
BA.10A.CNY.001.01.10.GB
4. Mounting, installation and connection
4.1 Inspection before pump
installation
4.1.1 Check failure-free running of the
impeller
Check the failure-free impeller running in this way:
1. Remove motor shroud
1
.
2. Remove fan cover of motor.
3. Consider direction of rotation (arrow).
4. Rotate shaft slowly by hand via the fan.
The shaft must rotate easily. If the impeller rubs against the
pump casing (for example due to transport damage) it has
been damaged.
When the impeller rubs against the casing: Contact
HILGE Service.
When the impeller runs failure free:
5. Re-fit fan cover of the motor.
6. Re-fit motor shroud
1
.
4.2 Set-up and alignment of the
pump assembly
W A R N I N G
!
Danger of misalignment of the pump due to an improper foun-
dation.
A misaligned pump due to an improper foundation can cause
death, grievous bodily harm or damage to the plant.
•
Ensure that the foundation on which the pump is set up is
clean and flat and has sufficient load capacity.
•
Mount the pump – especially when it is to be set up verti-
cally
2
– with the use of suitable heavy-duty anchors. As
the centre of gravity is higher, the pump can tip.
Overview
This chapter is intended for the maintenance and repair personnel.
This section describes how to mount, adjust and install the pump.You get to know what to consider when you
connect the pump to the electric mains supply and how to improve the flow in order to avoid dry running of the
shaft seals.