GB
GB
F
E
25
96440-02.2020-DGbRu
View X
•
Oil sight glass
•
Possibility to connect to oil level regulator
Fig. 34
1
2
4
°
124
°
12
4°
Ø 47,6
1
2
4
°
Three-hole connection for oil level regulator
make ESK, AC+R, CARLY (3 x M6, 10 deep)
Three-hole connection for oil level regulator
make TRAXOIL (3 x M6 x 10 deep)
9
|
Dimensions and connections
SV
DV
Suction line
Discharge line see technical data, Chapter 8
A
Connection suction side, not lockable
1/8“ NPTF
A1
Connection suction side, lockable
7/16“ UNF
B
Connection discharge side, not lockable
1/8“ NPTF
B1
Connection discharge side, lockable
7/16“ UNF
B2
Connection discharge side, not lockable
7/16“ UNF
C
Connection oil pressure safety switch OIL
7/16“ UNF
D
Connection oil pressure safety switch LP
7/16“ UNF
D1
Connection oil return from oil separator
5/8“ UNF
E
Connection oil pressure gauge
7/16“ UNF
F
Oil drain plug
M22x1.5
H
Oil charge plug
M22x1.5
J
Connection oil sump heater
M22x1.5
K
Sight glass
3 x M6
L
Connection thermal protection thermostat
1/8“ NPTF
ÖV
Connection oil service valve
1/4“ NPTF
P
Connection oil pressure differential sensor
M20x1.5
Q
Connection oil temperature sensor
1/8“ NPTF