Mounting
Setting up animal segregation
7159-9001-108
01. February 2020
5.8.2
Installing the control valve
1. Mount the control valve on the vacuum line, close to the vacuum cylinder, using
a pipe clip and gasket. (170, 180, 190)
Note:
Observe the control valve's installation position!
Use one control valve per cylinder.
Item
Part No.
Description
Qty.
7159-5530-010
Gate frame
SG1 (2-3ways)
7159-5487-010
Segregation gate, complete
0170
7071-2780-070
Control valve complete
5/2 14-14R / 24 V-DC
1
0180
7009-3270-050
Tapping pipe clip, complete
2in / G0,5in
1
0190
0007-2216-750
Sealing collar
19x27x4
1
Item
Part No.
Description
7009-3270-050
Tapping pipe clip, complete
2in / G0,5in
0010
0004-5259-880
Gasket
12x18x2
0010
0004-5259-880
Gasket
12x18x2
0020
0019-6113-300
Cylindrical head screw
4762 M 6x40
2. Run vacuum hoses from the vacuum cylinder to the control valve and connect.
For more information on this subject, please refer to the section on
Connecting animal segregation