background image

AZ41E09DAB

GE Zoneline

®

 Deluxe Series Cooling and Electric Heat Unit

Specification Created 12/09

390588

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service,  

800.626.2000.

Electrical Wiring

All wiring, including installation of receptacle, must  

be made in accordance with local electrical codes  

and  regulations.

Note:

 Aluminum wiring may pose special problems –  

consult a qualified electrician.

Grille Options

Stamped Aluminum Grille – RAG60
Exterior Architectural Louvers Durable Polycarbonate:
RAG61 (Beige) 

RAG63 (Bittersweet)

RAG62 (Maple) 

RAG67 (Extruded Aluminum)

Retrofit Kits:

RAK901L – Wall Case Insulation for use with heat pumps. 

RAK40 – Deflector Kit to adapt chassis for use with  

existing exterior architectural louvered grilles.

Ducted Applications

4100 and 6100 series can be used with ductwork to heat or cool more than one room. RAK6052 

Duct Adaptor is applied to top of case over air discharge/RAK601 Duct Extension is applied 

to right or left of adaptor. Locally fabricated ductwork may be added to extend to maximum 

recommended distance of 15 feet.

Electrical Connection

230/208 volt units may be plugged into a receptacle. 265 volt units are provided with a junction box 

and require direct connection. (NEC Requires 265V Direct Connection) See Architects and Engineers 

Design Data Manual for  electrical connection information including use of sub-base for direct 

connected units. Installation must  comply with local electrical codes and regulations.

Power Connection kits required on all Zoneline chassis.

Wall Case Dimensions

RAB71 Wall Sleeve

  Heavy-gauge galvanized steel, with insulation.  

  A  – 42",  B – 13-3/4",  C – 16"

RAB77 Wall Sleeve

   Molded SMC fiberglass-reinforced polyester 

compound.  

A – 42-1/8",  B– 13-7/8",  C – 16-1/4

Wall Opening Dimensions

  Add 1/4" to A and C dimensions for all cut-out size. 

  RAB71 16-1/4" Min. H x 42-1/4" Min. W 

  RAB71 available in 16",  24",  28" and 31" depths 

  RAB77 16-1/2" Min. H x 42-3/8" Min. W

Maximum Cord Extension (in inches)

SIDE

VIEW

Inside

Room

  Cabinet

Outside

58

21

Grille

7-1/8

RAB71A = 16
RAB77A = 16-1/4

RAB71A = 20-7/8
RAB77A = 21

Room Air/Installation QSart

230/208 Volt Line Cord Connected Units

Line Cord   

Kit

Electric Heat 

(Btuh)

Electric  

Heater Watts

Electric  

Heat Amps

Min. Circuit 

Protection 

(Amps)

RAK3153A

8,600/7,100

2,550/2,090

11.6/10.6

15

RAK3203A

11,700/9,600

3,450/2,820

15.5/14.1

20

RAK3303A

17,000/13,900

5,000/4,090

22.3/20.3

30

230/208 Volt Sub-Base Connected Units

Sub-Base

Electric Heat 

(Btuh)

Electric  

Heater Watts

Electric  

Heat Amps

Min. Circuit 

Protection 

(Amps)

RAK204D15P

8,600/7,100

2,550/2,090

11.6/10.6

15

RAK204D20P 11,700/9,600

3,450/2,820

15.5/14.1

20

RAK204D30P 17,000/13,900

5,000/4,090

22.3/20.3

30

Dimensions and Installation Information (in inches)

 