Wiegand Interface Unit Two-State (WIU-2)

Installation Manual

Summary of Contents for WIU-2

Page 1: ... 852 2142 5063 Australia T 61 3 9259 4700 F 61 3 9259 4799 Europe T 32 2 725 11 20 F 32 2 721 86 13 Latin America T 305 593 4301 F 305 267 4300 www gesecurity com 2008 General Electric Company All Rights Reserved 460579001F 10 08 Wiegand Interface Unit Two State WIU 2 Installation Manual ...

Page 2: ...atents GE and the GE monogram are registered trademarks of General Electric Wiegand Interface Unit Two State WIU 2 product and logo are trademarks of GE Security Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products Intended use Use this product only for the purpose it was designed for refer to the data sheet a...

Page 3: ... 5 Parts list 6 Installation overview 6 Mounting the WIU 2 7 Configuring the WIU 2 8 J1 Reader interface connector 10 J2 Controller interface connector 11 J3 Two state reporting connector 11 J5 Reserved 11 J6 HID reader supervision 11 Connecting the WIU 2 12 Wiring diagrams 13 Testing the WIU 2 15 Troubleshooting the WIU 2 16 Regulatory approvals 16 UL 16 CE 17 ...

Page 4: ...IU 2 Installation Manual ii Figures Figure 1 Mounting instructions 7 Figure 2 WIU 2 connectors and jumpers 9 Figure 3 Sample WIU 2 configuration 12 Figure 4 WIU 2 to M5 8RP Interface 13 Figure 5 WIU 2 to M2000PX or M2000PXN Interface 14 ...

Page 5: ...cure location The Wiegand Interface Unit Two State WIU 2 board features a Wiegand data converter which can accommodate both conventional and proprietary Wiegand reader protocols and includes a 2 Amp relay for door strike control entrance exit activity With the WIU 2 card any organization can quickly add a wide range of Magnetic Stripe Wiegand Proximity Mifare and Biometric readers to any GE access...

Page 6: ...measures WARNING Circuit board components are vulnerable to damage by electrostatic discharge ESD ESD can cause immediate or subtle damage to sensitive electronic parts An electrostatic charge can build up on the human body and then discharge when you touch a board A discharge can be produced when walking across a carpet and touching a board for example Before handling any board make sure you diss...

Page 7: ...both traditional and custom Wiegand BID formats to GE F 2F supervised protocol Centralizes wiring connections for remote access control readers door strike hardware door contact and request to exit REX circuitry Includes a heavy duty 2 Amp door strike relay Supports up to 24 VAC or 30 VDC door strikes Connector compatible with popular 2 state interface adapters Note The WIU 2 does not support keyp...

Page 8: ...s on page 16 Host software Secure Perfect Edition 3 0 or later Picture Perfect 1 7 or later FCWnx Controllers M5PX with 2RP or 8RP M5PXN with 2RP or 8RP M5PXNplus with 2RP or 8RP M2000PX M2000PXN M2000PXNplus M3000PXNplus with 2RP or 8RP Readers Formats up to 40 bits Wiegand data formats 26 bit 32 bit 35 bit Corporate 1000 37 bit 40 bit GE formats ...

Page 9: ...maximum cabling distance of 1 000 ft 304 8 meters is influenced by wire gauge reader power requirements and the 12 VDC level from the controller c WIU 2 to Reader The maximum cabling distance of 250 ft 76 20 meters is influenced by wire gauge reader power requirements minimum input voltage at the reader when using the 12 VDC from the WIU 2 originally from the controller and the cabling between the...

Page 10: ...ling the Wiegand Interface Unit 2 Each step is explained in further detail in the sections that follow 1 Mount the WIU 2 Refer to Mounting the WIU 2 on page 7 Note The WIU 2 must be mounted indoors in a protective enclosure or standard 1 gang electrical box installer supplied as shown in Figure 1 2 Configure the WIU 2 Refer to Configuring the WIU 2 on page 8 3 Connect the WIU 2 Refer to Connecting...

Page 11: ...it with the alcohol wipes provided in the mounting hardware kit 2 Apply the four standoffs provided in the mounting hardware kit to the four corners of the WIU 2 board as shown in Figure 1 3 Remove the adhesive liner on the standoffs and attach the WIU 2 board to the electrical box cover making sure the WIU 2 board does not interfere with or touch the sides of the electrical box ...

Page 12: ...llation Manual 8 Configuring the WIU 2 The following connectors and jumpers make up the Wiegand Interface Unit 2 J1 Reader Interface Connector J2 Controller Interface Connector J3 2 State Reporting Connector J5 Reserved J6 HID Reader Supervision ...

Page 13: ...Configuring the WIU 2 9 Figure 2 WIU 2 connectors and jumpers J6 J3 J1 J2 ...

Page 14: ...ct a Wiegand output device to the WIU 2 Table 1 J1 Reader interface connector PIN Description 1 Door ground return 2 Door input 3 REX ground return 4 REX input 5 Wiegand Data 1 6 Wiegand Data 0 7 Door DO LED control Used to control door strike and activate green LED 8 Beeper Signal switches to ground to activate the beeper 9 Ground 10 12 VDC fused power 250 mA maximum ...

Page 15: ...ve the jumper to disable 2 state reporting J5 Reserved The 2 pin connector J5 is reserved J6 HID reader supervision The 2 pin connector J6 is the HID reader supervision connector By default this connector is not jumpered and HID reader supervision is disabled Place a jumper over this connector to enable HID reader supervision Table 2 J2 Controller interface connector PIN Description 1 12 VDC power...

Page 16: ... the WIU 2 Connect the WIU 2 between the GE controller and access control reader as indicated in Figure 3 Figure 3 Sample WIU 2 configuration It is important to ensure all connections are made prior to applying power WIU 2 Typical controller M5 shown Typical Wiegand reader ...

Page 17: ...Connecting the WIU 2 13 Wiring diagrams Figure 4 WIU 2 to M5 8RP Interface ...

Page 18: ...Wiegand Interface Unit Two State WIU 2 Installation Manual 14 Figure 5 WIU 2 to M2000PX or M2000PXN Interface ...

Page 19: ...mper J6 has been removed 4 If an incorrect badge ID BID displays on the host check for crossed lines between the WIU 2 and the reader See Figure 4 WIU 2 to M5 8RP Interface on page 13 or Figure 5 WIU 2 to M2000PX or M2000PXN Interface on page 14 as appropriate 5 Do not jumper or short DO LED located on J2 pin3 to the Pin light located on connector J1 pin7 For proper LED and pin light operation wir...

Page 20: ...ystem Always verify wiring against the wiring diagrams before powering up the system Regulatory approvals UL The following are the results of the UL evaluation of the WIU 2 readers Operating temperature range 32 F 0 C to 120 F 49 C Relative humidity 85 For UL Listed installations the WIU 2 must be mounted within the protected area of a protective enclosure UL Listed Installations ...

Page 21: ...io A sample of the product has been tested by PSE 12955 Bellamy Brothers Blvd Dade City FL 33525 PSE 12955 Bellamy Brothers Blvd Dade City FL 33525 Test report reference 07F260I 03F246C Applied standards EN50130 4 1995 A1 1998 A2 2003 EN 55022 1998 Equipment class identifier RF products falling under the scope of R TTE x Not Applicable None class 1 product class 2 product Means of conformity We de...

Page 22: ...Wiegand Interface Unit Two State WIU 2 Installation Manual 18 ...

Page 23: ...Regulatory approvals 19 ...

Page 24: ...Wiegand Interface Unit Two State WIU 2 Installation Manual 20 ...