March 2004
4-6
Configuring Meter Data
Resetting Forward and
Reverse Totals
On occasion, you may need to clear and reset the forward and reverse
totals computed by the Forward and Reverse Totalizers. To reset the
totals:
1.
Press [ESC]. The UTX878 enters the
User Program.
2.
Press the [
X
] key until
CONFIG
is bracketed and press [ENT].
3.
Press the [
T
] key until
Reset Totals
is highlighted. Then press
[ENT].
4.
The next window asks you to choose the
Channel
(1 or 2). Use the
[
S
] and [
T
] keys to scroll to the desired channel and press
[ENT].
5.
The next screen displays three choices:
Reset Fwd Total, Reset
Rev Total
or
Reset Both
. Scroll to the desired choice and press
[ENT].
What’s Next?
You have finished entering data in the
CONFIG
menu. Do one of the
following:
•
To program in other menus, refer to Appendix A,
Menu Maps
, to
navigate to the desired menu.
•
To return to the display screen, press [ESC] until the display screen
reappears.
Summary of Contents for UTX878 Ultrasonic
Page 2: ...iii March 2004 The UTX878 Flow Transmitter and Transducers ...
Page 8: ...Chapter 1 ...
Page 20: ...March 2004 Installation 1 11 Figure 1 5 UTX878 Outline and Installation Dwg 712 1196 rev 2 ...
Page 22: ...March 2004 Installation 1 13 Figure 1 7 UTX878 Wiring Diagram Dwg 702 528 rev 2 ...
Page 23: ...Chapter 2 ...
Page 45: ...Chapter 3 ...
Page 52: ...Chapter 4 ...
Page 60: ...Chapter 5 ...
Page 65: ...Chapter 6 ...
Page 75: ...Chapter 7 ...
Page 80: ...Appendix A ...
Page 85: ...Appendix B ...
Page 86: ...CE Mark Compliance Introduction B 1 EMC Compliance B 1 ...
Page 88: ...Appendix C ...
Page 89: ...Data Records Site Data C 1 ...
Page 93: ...Appendix D ...
Page 94: ...Service Record Introduction D 1 Data Entry D 1 Diagnostic Parameters D 3 ...