C.7 LOGICAL NODES
C
C.7LOGICAL NODES
C.7.1 LOGICAL NODES TABLE
The UR-series of relays supports IEC 61850 logical nodes as indicated in the following table. Note that the actual instantia-
tion of each logical node is determined by the product order code. For example. the logical node “PDIS” (distance protec-
tion) is available only in the D60 Line Distance Relay.
Table C–1: IEC 61850 LOGICAL NODES (Sheet 1 of 3)
NODES
UR-FAMILY
L: SYSTEM LOGICAL NODES
LPHD
: Physical device information
Yes
LLN0
: Logical node zero
Yes
P: LOGICAL NODES FOR PROTECTION FUNCTIONS
PDIF
: Differential
Yes
PDIR
: Direction comparison
---
PDIS
: Distance
Yes
PDOP
: Directional overpower
---
PDUP
: Directional underpower
---
PFRC
: Rate of change of frequency
---
PHAR
: Harmonic restraint
---
PHIZ
: Ground detector
---
PIOC
: Instantaneous overcurrent
Yes
PMRI
Motor restart inhibition
---
PMSS
: Motor starting time supervision
---
POPF
: Over power factor
---
PPAM
: Phase angle measuring
---
PSCH
: Protection scheme
---
PSDE
: Sensitive directional earth fault
---
PTEF
: Transient earth fault
---
PTOC
: Time overcurrent
Yes
PTOF
: Overfrequency
---
PTOV
: Overvoltage
Yes
PTRC
: Protection trip conditioning
Yes
PTTR
: Thermal overload
Yes
PTUC
: Undercurrent
---
PTUV
: Undervoltage
Yes
PUPF
: Underpower factor
---
PTUF
: Underfrequency
---
PVOC
: Voltage controlled time overcurrent
---
PVPH
: Volts per Hz
---
PZSU
: Zero speed or underspeed
---
R: LOGICAL NODES FOR PROTECTION RELATED FUNCTIONS
RDRE
: Disturbance recorder function
---
RADR
: Disturbance recorder channel analogue
---
RBDR
: Disturbance recorder channel binary
---
RDRS
: Disturbance record handling
---
RBRF
: Breaker failure
Yes
RDIR
: Directional element
---
RFLO
: Fault locator
Yes
RPSB
: Power swing detection/blocking
Yes
RREC
: Autoreclosing
Yes
Summary of Contents for UR T60
Page 10: ...x T60 Transformer Protection System GE Multilin TABLE OF CONTENTS ...
Page 14: ...xiv T60 Transformer Protection System GE Multilin 0 1 BATTERY DISPOSAL 0 BATTERY DISPOSAL 0 ...
Page 34: ...1 20 T60 Transformer Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 436: ...5 298 T60 Transformer Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 678: ...C 30 T60 Transformer Protection System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Page 688: ...D 10 T60 Transformer Protection System GE Multilin D 1 IEC 60870 5 104 PROTOCOL APPENDIX D D ...
Page 700: ...E 12 T60 Transformer Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...