2.1 INTRODUCTION
2 PRODUCT DESCRIPTION
2
Figure 2–1: SINGLE LINE DIAGRAM
2.1.2 SECURITY
The following security features are available:
•
Password security — Basic security present in the default offering of the product
•
EnerVista security — Role-based access to various EnerVista software screens and configuration elements. The fea-
ture is available in the default offering of the product and only in the EnerVista software.
•
CyberSentry security — Advanced security options available as a software option. When purchased, the options are
automatically enabled, and the default Password security and EnerVista security are disabled.
Changing the password, or any other setting, does not take the relay out of service. The relay is taken out of service when
a settings file is written to it.
Table 2–2: OTHER DEVICE FUNCTIONS
FUNCTION
FUNCTION
FUNCTION
Breaker arcing current (I
2
t)
DNP 3.0 or IEC 60870-5-104
communications
Oscillography
Breaker control
Ethernet Global Data protocol (optional)
Setting groups (6)
Breaker restrike
Event recorder
Teleprotection inputs and outputs
Contact inputs (up to 96)
Fault detector and fault report
Time synchronization over IRIG-B or IEEE
1588
Contact outputs (up to 64)
FlexElements™ (16)
Time synchronization over SNTP
Control pushbuttons
FlexLogic equations
Transducer inputs and outputs
CyberSentry™ security
IEC 60870-5-103 communications
(optional)
User-definable displays
Data logger
IEC 61850 communications (optional)
User-programmable LEDs
Demand
Incipient cable fault detection
User-programmable pushbuttons
Digital counters (8)
Metering: current, voltage, power, energy,
frequency, harmonics, THD
User-programmable self-tests
Digital elements (48)
Modbus user map
Virtual inputs (64)
Direct inputs and outputs (32)
Non-volatile latches
Virtual outputs (96)
Disconnect switches
Non-volatile selector switch
832738A9.CDR
52
50G
51G
Same functions as breaker 1
For breaker 1
51P
51_2
50N
51N
81U
59N
59X
27P
27X
Metering
2
3
4
5
F35 Multiple Feeder Protection System
Monitoring
CLOSE
TRIP
79
Transducer
inputs
TM
FlexElements
50P
50_2
32N
49
Summary of Contents for UR F35 Series
Page 10: ...x F35 Multiple Feeder Protection System GE Multilin TABLE OF CONTENTS ...
Page 366: ...5 238 F35 Multiple Feeder Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 426: ...10 12 F35 Multiple Feeder Protection System GE Multilin 10 6 DISPOSAL 10 MAINTENANCE 10 ...
Page 454: ...A 28 F35 Multiple Feeder Protection System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 620: ...F 12 F35 Multiple Feeder Protection System GE Multilin F 2 DNP POINT LISTS APPENDIX F F ...
Page 630: ...H 8 F35 Multiple Feeder Protection System GE Multilin H 3 WARRANTY APPENDIX H H ...
Page 640: ...x F35 Multiple Feeder Protection System GE Multilin INDEX ...