Chapter 4. Basic Programming
40
TMO2D Digital Display User’s Manual
4.8.3b Pressure Compensation:
In the TMO2D, pressure (PRES) compensation is typically used only with a TMO2 oxygen transmitter. Pressure
compensation will correct the oxygen readings for any changes in atmospheric pressure. If you have selected pressure
compensation, you must enter both transducer data and pressure grid data.
The display will briefly show “Working . . .” before proceeding to the next question.
.
The display again shows “Working . .
.”
before returning to the start of the
Gas Calibration?
submenu.
4.8.3c Background Compensation:
Background gas compensation in the TMO2D is typically used with a TMO2 oxygen transmitter to correct the readings
for changes in background gas concentrations. If you have selected background compensation (BKGD), you must enter
background grid data.
Note:
Each curve must have AT LEAST TWO entered data points.
PRESSURE GRID ENTRY
# of Curves?[X]:
Use the numeric keys to enter the number of pressure curves, then press [YES] twice
to confirm the entry.
Curve # 1
mmHg [XXX.X]:
Use the numeric keys to enter the pressure in mmHg for the first curve, and press
[YES] twice. Repeat this process for the other curves.
PRESSURE GRID ENTRY
# of Points?[X]:
Use the numeric keys to enter the number of oxygen points per pressure curve, then
press [YES] twice to confirm the entry.
Point # 1
%O
2
[XX.XX]
Use the numeric keys to enter the percent of oxygen for the given point, then press
[YES] twice to confirm the entry. Repeat this process for the other points.
X.XX% O
2
, XXX.X mmHg
Enter Point? [[YES]] no
The display will show the data entered for Curve #1, and ask if you wish to enter a
point. Use the [NO] or arrow keys to scroll between choices, and press [YES] to
confirm either a [YES] or [NO] selection. (If you select [NO], the menu proceeds to
the next point entered.)
X.XX% %O
2
, XXX.X mmHg
O
2
mA [X.XX]:
Use the numeric keys to enter the corresponding mA value for the given point, then
press [YES] twice to confirm the entry. Repeat this process for the other points.
O
2
GRID ENTRY
# of Curves [X]:
Use the numeric keys to enter the number of background gas curves, then press
[YES] twice to confirm the entry.
O
2
GRID ENTRY
# of Points [X]:
Use the numeric keys to enter the number of oxygen points per curve, and press
[YES] twice to confirm the entry.
Point #1:
%O
2
[X.XX]:
Use the numeric keys to enter the percent gas concentrations for each point, then
press [YES] twice to confirm the entry.
Summary of Contents for TMO2D
Page 1: ...GE Measurement Control Solutions Gas Moisture TMO2D Digital Display User s Manual ...
Page 4: ...ii ...
Page 10: ...Chapter 1 Features and Capabilities 2 TMO2D Digital Display User s Manual ...
Page 24: ...Chapter 2 Installation 16 TMO2D Digital Display User s Manual ...
Page 26: ...Chapter 2 Installation TMO2D Digital Display User s Manual 18 ...
Page 72: ...Chapter 6 Specifications 64 TMO2D Digital Display User s Manual ...
Page 74: ...Appendix A Outline and Installation Drawings 66 TMO2D Digital Display User s Manual ...
Page 86: ...Appendix B Menu Maps 78 TMO2D Digital Display User s Manual ...
Page 92: ...Appendix B Menu Maps TMO2D Digital Display User s Manual 84 ...
Page 96: ...Index 88 TMO2D Digital Display User s Manual ...
Page 98: ...Warranty 90 TMO2D Digital Display User s Manual ...
Page 100: ......
Page 101: ......