• Supports Tetra miniMAX, Tetra MAX, Tetra PowerMAX
and Tetra PowerStrip LED lighting systems
• Class 2 wiring per NEC Article 725 (SELV)
• Damp location rated
• IP66 rated: separate enclosure required
(GEPS12-60 & GEPS12-60U)
Tetra
®
LED Systems Power Supply
12
Volt
GE
Lighting Solutions
Installation Guide
imagination at work
Power Supply Features
Power Supply Installation
1
Connect the AC line to the black
(line) and white (neutral) input
wires of the power supply using
18-14 AWG (0.82-2.08 mm
2
) or
18-10AWG (0.82-5.26 mm
2
) twist-on
wire connectors.
NOTE:
Power Supply Loads
Exceeding maximum load will cause the
power supply to shut down. Once the
excess load is removed, cycle the input
power to restart the power supply.
Specific load information for the supported
LED systems can be found in the
“Power
Supply Specifications”
section on the next
page.
NOTE:
For CSA approval, a disconnect/
toggle switch of appropriate rating needs
to be placed within 29 feet (8.84 meters)
of primary side of the power supply. The
minimum rating of the switch must be
either 120 or 220 Volts AC. The switch
must also support twice the amount of
input current.
Connect the supply wire that is
attached to the Tetra LED System to
the red (+) and black (-) output wires
of the power supply as outlined
in the
“Electrical Connections”
section of your LED system’s
Installation Instructions.
2
RISK OF ELECTRIC SHOCK:
• Disconnect power at fuse box or circuit breaker before servicing or
installing product.
• Properly ground Tetra
®
power supply.
RISK OF FIRE:
• Use only Tetra
®
supply wire to make connection from Tetra
®
power
supply to Tetra
®
LED strip.
• Use only approved wire for input/output connection.
Minimum size 18 AWG (0.82mm
2
)
• Follow all local codes.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l’alimentation électrique à la boîte de fusibles ou au
disjoncteur avant l’entretien ou l’installation du produit.
• Assurez-vous de correctement mettre à terre l’alimentation
électrique Tetra
®
.
RISQUES D’INCENDIE
• N’utilisez que le fil d’approvisionnement Tetra® pour faire la
connexion entre l’alimentation Tetra
®
et la bande DEL Tetra
®
.
• N’utilisez que des fils approuvés pour les entrées/sorties de
connexion. Taille minimum 18 AWG (0.82mm
2
).
• Respectez tous les codes locaux.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
WARNING/AVERTISSEMENT
Input
wires
White (neutral)
Black (line)
AC line
To Tetra LED System
Output
wires
Red (+)
Black (-)