background image

RHM 100

g

The RHM 100 can measure flow rates up to 720 
t/h (26,455 lb/min) with pressures up to 189 bar. 
This large sized model is optimal for loading and 
unloading applications - manufactured by GE’s 
Rheonik mass flowmeter experts.

Applications

• Loading of boats, vessels, rail tank wagons

• Highly viscous media (low pressure drop and 

excellent performance at low flow conditions)

Features

• Suitable for pressure up to 189 bar

• Flow uncertainty down to 0.15%

• Density uncertainty down to 0.5%

• Repeatability better than 0.05%

• Unique torsion oscillator

• Typical measuring ranges from 300 to 12000 kg/

min

• Minimal flows as low as 200 kg/min

• Heavy duty version available (increased wall 

thickness of measuring loops for additional safety)

• Customization possible

Coriolis Mass Flowmeter 

for High Flow Applications

• Hazardous Area Approvals (ATEX, CSA, ...)

Advantages

• High flow rates for fast filling, in combination with 

high operating pressure

• Torsion oscillator design assures most stable and 

basically drift free measurement and increased 
signal to noise ratio

• Not sensitive to changes in pressure

• Longest life time and increased safety (low stress 

in welds and increased wall thickness against 
abrasion)

• No moving parts, practically no maintenance

GE

Measurement & Control

Summary of Contents for RHM 100

Page 1: ...rsion oscillator Typical measuring ranges from 300 to 12000 kg min Minimal flows as low as 200 kg min Heavy duty version available increased wall thickness of measuring loops for additional safety Customization possible Coriolis Mass Flowmeter for High Flow Applications Hazardous Area Approvals ATEX CSA Advantages High flow rates for fast filling in combination with high operating pressure Torsion...

Page 2: ... thickness of measuring loops may change by 10 pmax of P0 measuring loops standard M1 standard material 1 4571 316Ti OD x WT 114 3 x 4 5 mm 4 5 x 0 177 in bar C psi F 73 50 1059 122 66 120 957 248 57 210 827 410 pmax of PA measuring loops M1 standard material 1 4571 316Ti OD x WT 114 3 x 6 mm 4 5 x 0 236 in bar C psi F 99 50 1436 122 88 120 1276 248 76 210 1102 410 2 Process Connection Face to fac...

Page 3: ... Rate kg min Uncertainty DP bar Flow Rate kg min Uncertainty DP bar Repeatability Better 0 1 of rate Goldline 0 05 Density Down to 0 5 uncertainty Temperature Better 1 C Flow Rate kg min Nominal flow Qnom refers to roughly 8 10 m s 26 33 ft s velocity in measuring loops for best performance Selected sensors are only available in combination with temperature options T1 TA standard material and pres...

Page 4: ...200 PN16 Form C EN 1092 1 Form B1 D2 Flange DIN DN200 PN40 Form C EN 1092 1 Form B1 A1 Flange ANSI 8 150 RF SF A2 Flange ANSI 8 300 RF SF A3 Flange ANSI 8 600 RF SF Others on request RHM 100 Basic Order Code RHM 100 Temperature Range NT Models from 20 to 120 C 4 to 248 F ET Models from 45 to 120 C 49 to 248 F ET2 Models from 45 to 210 C 49 to 410 F ET1 Models from 196 to 50 C 320 to 122 F Heating ...

Reviews: