2.
A. Connect length of copper building wire to
range terminal block.
B. Splice copper wires to aluminum wiring using
special connectors designed and
approved
for joining copper to aluminum, and follow the
connector manufacturer’s recommended
procedure closely.
Wire used, location and enclosure of
splices, etc., must conform to good wiring
practice and local codes.
STEP 5
SYSTEM
SPECIAL GROUNDING INSTRUCTIONS
Frame grounded to neutral of appliance
through a link. If used in a MOBILE HOME or
if LOCAL CODES do not permit grounding
through the neutral:
1)
disconnect the link from neutral,
2) use grounding terminal or lead to ground
unit in accordance with local codes, and
3) connect neutral terminal or lead to branch
circuit in usual manner.
(If the appliance is to be connected by
means of a cord set, use 4-conductor cord
for this
purpose.) ,
CONNECTOR
BLOCK
4TH GROUNDING LEAD
y\
GROUND
LUG
STEP
b
ANTI-TIP BRACKET INSTALLATION
ANTI-TIP bracket is supplied with instructions
for installation in a variety of locations. The
instructions include a template, a parts list and a
list of tools necessary to complete the installation.
Read the IMPORTANT
INSTRUCTIONS
and the instructions that fit your situation before
beginning installation.
WARNING
1. Range must be secured by ANTI-TIP bracket
supplied.
2. See instructions to install (supplied with
bracket).
3. Unless properly installed, range could be
tipped by stepping or sitting on door. Injury
might result from spilled hot liquids or from
range
Typical installation of Anti-Tip bracket
Attachment to Wall
Bracket
STEP 7
LEVELING THE RANGE
The
range must be level. Leveling feet are located
at each corner of the base of the range. Remove
the storage drawer or kick panel (depending on
your model) and using channel locks, rotate the
leveling feet in and out as required to level the
range. (For instructions on how to remove and
replace the storage drawer or the kick panel, see
the Cleaning Under the Range section in Care
and Cleaning.) On some models, there are plastic
covers which may be removed for easy
adjustment
squeeze and pull).
One of the rear leveling feet will engage the
ANTI-TIP bracket (allow for some side to side
adjustment).
a minimum clearance of
between the range and the leveling foot that is to
be installed into the ANTI-TIP bracket.
Check the range for proper installation into the
ANTI-TIP bracket (after the range has been
properly installed) by grasping the edges of the
REAR burner holes and carefully attempting to
tilt the range forward.
STEP
FINAL CHECK
Be sure all switches are in the “off” position
before leaving the range.
29