READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
WARNING
FIRE AND SHOCK HAZARD
Ŷ
Always turn off power at the main power supply
before installing, cleaning or removing the
thermostat.
Ŷ
Do not use on voltages over 12 VDC. Higher
voltages will damage the thermostat and could cause
shock or fire hazards.
Ŷ
All wiring must conform to local and national
electrical and building codes.
Ŷ
Use this thermostat only as described in this manual.
Specifications
Electrical Rating:
12 VDC (Operating Range from 10.5 VDC - 14 VDC)
Changing Units Between Fahrenheit (°F) and Celsius (°C):
Simultaneously hold the Temp +/- buttons for 2 seconds.
Operating temperature Range:
0°F-115°F (-18°C-46°C)
Cooling Range:
60°F-85°F (15°C-30°C)
Heating Range
40°F-85°F (5°C-30°C)
Accuracy:
± 1°F (± 0.5°C)
Wall Thermostat Terminations:
0V (GND), Signal (COMMS), +12VDC
Wiring:
12 VDC Thermostat: Recommend AWG20 solid 3 copper wire
12 VDC Main Control: Recommend AWG18 stranded 2
copper wire
120 VAC Main Control: Recommend AWG12 solid copper
wire