Chapter 4  Detailed Operation 

4-33 

 

 

 

 

 

 

 

 

 

 

 

  

  

 

4

 

Memory 

The QuickPanel View supports a variety of memory subsystems to ensure the 
requirements of your application are met. All system memory is tied directly to 
the microprocessor‟s address and data busses for fastest access. To increase 
DRAM by up to 64 MB, a 100-pin DIMM memory expansion slot is also 
included. You can increase DRAM to a maximum of 96MB. 

Flash Memory  

This 32 MB block of non-volatile memory is the main long-term program 
storage for the QuickPanel View, operating like a virtual hard drive from the 
point of view of Windows CE. It is divided into two areas, of which only one is 

accessible from Windows CE Explorer. The 

 

 

Flash Storage

 folder 

represents a 16 MB block of memory available for long-term storage of user 
application programs. Another 16MB block is used to store the Windows CE 
operating system, and is not directly accessible from Windows CE Explorer.  

The operating system and all user application programs are transferred from 
Flash to DRAM for execution. Any user additions to the 

 

Windows

 folder are 

retained in 

 

 

Flash Storage 

when the 

 

Backup

 utility is run.  

FLASH memory has a limited write-cycle lifetime. That is, the physical memory 
devices wear out after approximately 100,000 cycles (minimum), so it is 
advisable to limit file operations such as copy, delete, etc.  

The write cycle is much slower for FLASH than it is for other portions of RAM, 
therefore FLASH is not recommended for the storage of program variables, or 
any data items whose values are dynamic.  

Flash memory can optionally be added with a CF card. These devices will 

appear as the 

 

 

PCFlash Storage

 folder. 

Summary of Contents for QuickPanel+ IC754VSI12CTD

Page 1: ...tforms Operator Interface Products 12 QuickPanel View Intermediate Color and Monochrome IC754VSI12CTD IC754VBI12CTD IC754VGI12CTD IC754VSI12MTD IC754VBI12MTD IC754VGI12MTD Hardware User s Guide GFK 23...

Page 2: ...he information contained herein does not purport to cover all details or variations in hardware or software nor to provide for every possible contingency in connection with installation operation or m...

Page 3: ...unavailable Technical Support Email support ip ge com Customer Care Email customercare ip ge com Primary language of support English Europe the Middle East and Africa Online Technical Support www ge i...

Page 4: ......

Page 5: ...ortfolio licenses such as and without limitation VC 1 and MPEG4 Part 2 Visual for the personal and non commercial use of a consumer to i Encode video in compliance with the standards licensed under su...

Page 6: ...EEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON HAZARDOUS Power input and output I O wiring must be in accordance with Class I Division 2 wiring methods Article 501 10 b of the National Electric Code...

Page 7: ...Locations 3 4 Mounting the QuickPanel View in a Panel 3 5 Detailed Operation 4 1 Touch Screen Display 4 2 Soft Input Panel 4 10 Communication Ports 4 13 CF Port 4 21 Ethernet 4 23 Printing 4 28 Expans...

Page 8: ...ntents iv 12 QuickPanel View Intermediate Color and Monochrome December 2010 GFK 2306E Calendar Clock A 5 Agency Approvals A 6 Diagnostics B 1 Power up B 1 Pocket Internet Explorer B 1 Physical Unit B...

Page 9: ...one microcomputer designed for maximum flexibility The design based on an advanced XScale microprocessor brings together a high resolution touch screen operator interface with a variety of I O options...

Page 10: ...a DC power supply via the supplied quick connect plug Depending on your application you may also want to connect and configure optional input devices communications ports and expansion adapters see ch...

Page 11: ...start the QuickPanel View 1 Apply DC power to the QuickPanel View Once power is applied the QuickPanel View begins initializing The first thing to appear on the display is the splash screen 2 To skip...

Page 12: ...power failure or other unplanned shutdown of the QuickPanel View In general programs are retained in FLASH memory and user data can be retained in battery backed SRAM Some operating system settings a...

Page 13: ...mware Updates Updates to the QuickPanel firmware are made available through the Support web site This will allow updating the unit to the most recent released version of the firmware with the latest f...

Page 14: ...wing user accessible controls and indicators and a block diagram showing module functions QuickPanel View Software 2 5 Working with Windows CE working with Pocket Internet Explorer backing up registry...

Page 15: ...he following diagram shows the physical layout of the QuickPanel View and the locations of ports and connections Caution Remove power from the QuickPanel View before opening the back Working on a live...

Page 16: ...GFK 2306E Chapter 2 Overview 2 3 2 Physical Layout of QuickPanel View Hinged access cover for expansion and battery...

Page 17: ...s between them 32 MB DRAM DRAM Expansion 100 pin DIMM 64 MB max 32 MB Flash 512 KB EPROM Boot 512 KB BBSRAM Buffer Field Bus Expansion Proprietary Expansion XScale PXA255 Touch Screen Backlit LCD Disp...

Page 18: ...rning curve for users having experience with Windows 95 98 NT 2000 ME XP From a software developer s perspective the CE environment is a subset of the WIN32 application programming interface simplifyi...

Page 19: ...or Opens the Windows CE Start menu Use arrow keys to select a program and ENTER to run it ALT TAB Starts the Task Manager Use it to quit unresponsive programs CTRL ALT Starts the touch screen calibra...

Page 20: ...ipt components are included in the operating system and may be used by third party applications such as Proficy Machine Edition A connection can be established over a dial up connection default or an...

Page 21: ...2010 GFK 2306E 2 To configure a LAN Connection 1 Start Pocket Internet Explorer 2 From the Tools menu choose Options The Internet Options dialog box appears 3 On the Connection tab select the Use LAN...

Page 22: ...tion tab select the Access the Internet using a proxy server check box 4 In the Address box type the URL of your proxy server see your ISP or network administrator 5 In the Port box type the server s...

Page 23: ...p does the following It stores the Windows CE registry including any control panel settings in Flash memory It stores any changes or additions made to the Windows subtree of the file system in the use...

Page 24: ...g system then restarts the QuickPanel View This ensures all open files are closed properly To reboot the system 1 To save changes to system configurations run Backup see page 2 10 2 Tap Start point to...

Page 25: ...rrupted data volumes Storage Manager can repair data volumes existing either in Compact Flash CF or battery backed SRAM BBSRAM Data volumes existing in the main flash file system of the QuickPanel may...

Page 26: ...m Information window which provides information such as hardware version and serial number CPU type and specifications etc This information can be especially useful if you are contacting Technical Sup...

Page 27: ...opy Project to Flash Card icon on the desktop If there is more than one of the supported flash devices installed a Select Media confirmation dialog will appear allowing you to choose the destination l...

Page 28: ...e may or may not be enabled or may automatically update If there is more than one flash device with a valid project copy present a Select Media confirmation dialog will appear allowing you to choose w...

Page 29: ...an update image is present the user will be prompted to install this update as described above If the update dialogs are not closed the unit will not complete the boot cycle Always Restore With this s...

Page 30: ...econds will make this option operate the same as the Skip at Startup setting 4 Select OK to keep your setting choice To save the settings run Backup see page 2 10 Emulate PPC Emulate PPC is a utility...

Page 31: ...a script The HTTP utility is an executable EXE file included in the 12 QuickPanel View operating system The HTTP utility currently supports two file transfer commands COPY and DELETE Note In order to...

Page 32: ...txt Copies a file called MyFile txt on drive C of the local computer to the webfiles folder under the web server at MyServer Note that you can rename a file as you copy it HTTPUTIL DELETE url Where u...

Page 33: ...217 It does not support SFTP or implicit FTPS which uses different ports and is based on SSH rather than SSL All configuration of the FTP server is accomplished with the Secure FTP Server control pane...

Page 34: ...username password combination to be configured The server supports one username password combination to authenticate remote users There are three modes of authentication operation No support for anon...

Page 35: ...during reinsertion A server certificate is a special type of document that contains information about the server s settings and a chain of electronic signatures to guarantee the document has not been...

Page 36: ...2 From the command prompt type genslfcert CN unique identifier You may specify a unique identifier of your choice such as machine name machine location or IP address in place of unique identifier 3 A...

Page 37: ...Certificate Store screen appears 4 Specify whether Windows should place the certificate in a certificate store or select another location Click Next to continue The Completing the Certificate Import W...

Page 38: ...sure For ATEX applications a minimum panel thickness of 0 1 2 54mm is recommended For adequate ventilation allow at least 3 inches of space between adjacent equipment and all sides of the QuickPanel E...

Page 39: ...lowing diagram attach a 24VDC 48W power supply to the plug supplied with the QuickPanel View see Appendix A Specifications for power supply and conductor size requirements 2 Insert the plug into the p...

Page 40: ...avoid gasket degradation limit repeated insertions or removals of the unit and retightening of the mounting clips For full protection always use a fresh gasket Replacement gaskets may be ordered usin...

Page 41: ...ate Color and Monochrome December 2010 GFK 2306E 3 Mounting Bracket Locations To secure the QuickPanel View to a panel use the ten included mounting brackets They hook into openings located on the top...

Page 42: ...bezel channel and firmly tighten the clamp screws Note The torque range for the mounting clamp screws is 2 6 4 4 inch lbs 0 3 0 5 Nm The mounting clamps hold the unit in place by tension No drilling...

Page 43: ...compact flash CF port Ethernet 4 23 Setting an IP address Setting up access to a Windows network Accessing a remote resource on a Windows network Printing 4 28 Printing on Network Shared printers Expa...

Page 44: ...CTD and monochrome IC754VxI12MTD models incorporate a backlit 12 1 diagonal display employing active TFT technology The display in these models provides a resolution of 800 x 600 pixels The color mode...

Page 45: ...brightness 1 In the Control Panel double tap Display and choose the Brightness tab The Brightness dialog box appears 2 Drag the Brightness slider between Lowest and Highest 3 Tap OK to exit the contro...

Page 46: ...select backlight auto turn off 1 In the Control Panel double tap Display and choose the Backlight tab The Backlight dialog box appears 2 Select Auto turn off backlight while on external power 3 Tap OK...

Page 47: ...QuickPanel View is properly calibrated this translates into a grid of touch cells on the face of the display A blunt stylus should always be used during calibration for greatest accuracy During norma...

Page 48: ...Panel View Intermediate Color and Monochrome December 2010 GFK 2306E 4 To calibrate the touch screen 1 In the Control Panel double tap Stylus The Stylus Properties dialog box appears 2 Choose the Cali...

Page 49: ...n 4 7 4 3 Tap the Recalibrate button A cross hair target is displayed Note For greatest accuracy it is recommended that you use a blunt stylus when calibrating the touch screen 4 Follow the directions...

Page 50: ...Intermediate Color and Monochrome December 2010 GFK 2306E 4 5 Tap the screen to preserve the new setting or wait out the time limit to revert to previous settings 6 To save the settings run the Backup...

Page 51: ...The Stylus Properties dialog box appears 2 Choose the Double Tap tab 3 Double tap the grid to enter a setting 4 Double tap the test icon to check the setting If the test icon doesn t change when you...

Page 52: ...a standard hardware keyboard An icon in the system tray lets you view or hide the SIP Soft Input Panel icon To show hide the Soft Input Panel On the system tray of the task bar double tap the icon The...

Page 53: ...es dialog box appears 2 Select the Allow applications to change the input panel state check box 3 Select or clear the Show Input Panel in system tray check box 4 Tap OK 5 To save the settings run the...

Page 54: ...same thing as SHIFT but does not revert to lower case after another key is pressed Pressing the CAP key causes the Soft Input Panel to remain in upper case mode The CTRL and ALT keys behave the same...

Page 55: ...y A connection can be configured to reside on a network supporting a TCP IP protocol A DB25S female connector mounted on the bottom of the enclosure provides standard signals as described in the follo...

Page 56: ...do not specify the maximum number of nodes or devices that can be connected to a TIA EIA 422 or 485 network Instead the standards limit the number of electrical connections by specifying that a maximu...

Page 57: ...tied together The cable shield and signal ground should be connected together at only one device closest to the earth ground connection The signal and frame grounds of the QuickPanel View are capaciti...

Page 58: ...ion 1 From the Start menu tap Settings and then Network and Dial up Connections The Connection window appears 2 Double tap Make New Connection The Make New Connection window appears 3 Type a name for...

Page 59: ...le in the device list You can configure your device or TCP IP Settings at this time if you wish 7 Tap Finish for direct connection Device dialog box or Next for dial up Modem dialog box If you are add...

Page 60: ...and Dial up Connections The Connection window appears 2 Double tap Make New Connection The Make New Connection window appears 3 Type a name for the new connection 4 Choose a connection type Select Vi...

Page 61: ...2 10 To change the default device properties 1 From either the Device or Modem dialog box tap Configure The Device Properties dialog box appears 2 In the Port Settings tab choose settings for all con...

Page 62: ...s from your network administrator 2 From the Device Modem PPPoE Connection or VPN Connection dialog box tap TCP IP Settings The TCP IP Settings dialog box appears 3 Clear the Use server assigned IP ad...

Page 63: ...ld be toward the bottom Note For full protection from electrostatic discharge peel off the paper label on the side of the CF card facing the bezel to allow contact between the card and the internal fr...

Page 64: ...optional CF card may be ordered using part number IC754ACC0512MEM Caution Do not remove power while the system is writing to the CF card such as when copying a Proficy Machine Edition project Removing...

Page 65: ...cations You can connect an Ethernet network cable unshielded twisted pair UTP CAT 5 to the unit via the RJ45 connector on the bottom of the enclosure LED indicators on the port indicate channel status...

Page 66: ...thod You uniquely specify the numeric addresses for the QuickPanel View the Subnet Mask and the Default Gateway if applicable DHCP is the default on LAN1 The default on LAN2 is Manual with a setting o...

Page 67: ...net Mask and Default Gateway numbers obtained from your network administrator manual method only 8 Tap OK 9 To save the settings run the Backup utility See page 2 10 If the DHCP method was selected th...

Page 68: ...work 1 In the Control Panel double tap System The System Properties dialog box appears 2 On the Device Name tab in the Device name box type a unique name for your QuickPanel View In the Device descrip...

Page 69: ...The Explorer window appears 2 Type in the Address box or choose from a list the path to a remote resource For example MyRemoteComputer MyFolder specifies the folder named MyFolder on a computer with...

Page 70: ...rtrait orientation and disable color for print settings These setting also minimize the amount of memory needed to print a document The built in driver has a document spooling function to improve GUI...

Page 71: ...use of the server s IP for the server_name portion of the UNC Server_name is the text name of the printer server An IP address does not work here Printer_name is the printer port share name Do not con...

Page 72: ...before opening the QuickPanel View Working on a live unit may result in damage to equipment and injury to personnel Always use anti static precautions i e grounded wrist strap when accessing the inte...

Page 73: ...n forces the startup applications to run when the operating system is started When the switch is set to OFF the QuickPanel View operates normally displaying the startup splash screen You can skip runn...

Page 74: ...r supply before opening the QuickPanel View Working on a live unit may result in damage to equipment and injury to personnel Always use anti static precautions i e grounded wrist strap when accessing...

Page 75: ...MB block of memory available for long term storage of user application programs Another 16MB block is used to store the Windows CE operating system and is not directly accessible from Windows CE Explo...

Page 76: ...ed after their types of connection and order of attachment For example if you connect two flash memory devices one via the CF port and one via the FieldBus connector the first device connected is name...

Page 77: ...o provided by DRAM any data stored in DRAM will not be retained through a power cycle or reboot The split between program memory and storage memory may be adjusted as necessary to make more room for o...

Page 78: ...d used by each area is displayed numerically The blue bar indicates the current amount of unallocated DRAM and determines the boundaries within which the slider can move 3 Tap OK to apply the new sett...

Page 79: ...and injury to personnel Always use anti static precautions when accessing the interior of the QuickPanel View Caution Do not allow conductive material liquid or solid to contact the electronics of th...

Page 80: ...QuickPanel View s Power Properties control panel displays the status of the backup battery The Battery Very Low Or Missing icon appears in the taskbar when the battery is either missing or very low To...

Page 81: ...by installing or removing the battery accessed via the rear panel as shown in the following illustration Rear open Internal Battery Caution Disconnect the AC power from your DC power supply before op...

Page 82: ...of its carrier noting the arrow on the carrier indicating the direction of removal To install a new battery 1 Disconnect AC power from the DC supply 2 Open the rear access panel Note Battery must be i...

Page 83: ...lable Daylight saving time is enabled by a check box within the dialog box The time can be displayed in the system tray on the task bar To set the real time clock 1 In the Control Panel double tap Dat...

Page 84: ...e box adjust the hours minutes and seconds 8 Tap OK to finish 9 To save the settings run the Backup utility See page 2 10 To display the time on the taskbar 1 From the Start menu choose Settings and t...

Page 85: ...s for normal SNTP time server configuration because they are normally located on a closer network that can produce faster updates It is recommended that you research any time server selection to ensur...

Page 86: ...Tap Apply after making changes in any box 2 To add or modify SNTP settings select the SNTP tab 3 To enable SNTP ensure the Enable SNTP check box is selected 4 Enter the time server name in the Server...

Page 87: ...th 0 38 in 9 7 mm Weight 5 2 lb 2 36 kg DC Power Input Voltage 12 VDC 20 regulated power supply or 24 VDC 20 regulated power supply Power Dip Tolerance 30 nominal input voltage 10msec Insulation Resis...

Page 88: ...urs Note Backlight is not field replaceable Luminance 400 NITS Front Panel Bezel Material Valox 3706 For material specifications visit www gepolymerland com Membrane Material Lexan HP60 For material s...

Page 89: ...ot Form Factor 100 pin DIMM Memory Type SDRAM Maximum DRAM 64 MB Maximum Devices per Module Four Bus Width 32 bits Bus Speed 100 MHz or faster Voltage 3 3 VDC CAS Latency CL 3 Refresh Type Self Refres...

Page 90: ...alog Number 512 MB IC754ACC0512MEM FieldBus One slot Communication Ports Ethernet LAN1 IEEE 802 3 10 BaseT 100 Base TX Auto negotiate Full or half duplex RJ45 connector Two status LEDs per connector M...

Page 91: ...z 1 0g acceleration Operational Shock IEC 60068 2 27 15g 11ms sine wave Rated temperature limits refer to the ambient air temperature immediately surrounding less than 3 or 7 6 cm the QuickPanel insid...

Page 92: ...Directive European Safety for Hazardous Locations Equipment Group II Category 3 ATEX when mounted in an IP66 enclosure Certification in accordance with European directives refer to Declaration of Conf...

Page 93: ...This is further indicated when the left LED glows red The LED will turn red if either backlight fails Backlight timer expired Touch the screen to reactivate Pocket Internet Explorer Problem Suggested...

Page 94: ...n the system is first started observe the screen to notice any memory error messages from the boot loader If any messages appear such as DIMM not 12 row DIMM not 32 bit DIMM refresh unsupported power...

Page 95: ...D Diagnostics B 1 Dial up connection configuring 2 7 Dimensions bezel A 1 module A 1 panel cutout 3 3 DIP Switches 4 31 Display operation 4 2 specifications A 2 DRAM adding 4 37 DRAM memory 4 35 E Emu...

Page 96: ...r requirements A 1 Power supply connecting 3 2 Power up diagnostics B 1 Printing 4 28 Proxy server configuring 2 9 R Reboot 2 11 Remote resource accessing 4 27 Runtime setup 1 3 S Shutdown 1 4 SNTP se...

Reviews: