Dimension and installation information are shown in inches.

Specification Created 5/10

220247

PT916SR 

GE Profile

 30" Built-In Single Convection Wall Oven

 

KW Rating

240V

3.8

208V 2.8

Breaker Size

240V

20 Amps

208V 20 Amps

Most 30” Wall Cabinets can be used with this unit.
Note:
 These ovens are not approved for 

stackable installations. Cabinets installed 
adjacent to wall ovens must have an adhesion 
spec of at least a 194°F temperature rating.
Door handle protrudes 3" from door face. Cabinets 
and drawers on adjacent 45° and 90° walls should 
be placed to avoid interference with the handle.
Electric wall ovens are not approved for 

installation with a plug and receptacle. They 

must be hard wired in accordance with  

installation instructions
Installation Information: Before installing, consult 
installation instructions packed with product for 
 current dimensional data.
Side-by-side installations require at least 2" 
between cutouts.

CL

2 x 4 or

equivalent

runners

Suitable

bracing

to support

runners

21-5/8"

over centerline

of cabinet

(must support 275 lbs.)

Cutout width
28-1/2'' MIN.
28-5/8'' MAX.

29-3/4

C

30

Recommended 

cutout location 

32-1/2" 

from floor

21

Junction 

box

location

Allow minimum of 21'' for clearance

to adjacent corners, drawers, walls, or etc.
A=Allow 1" overlap of oven over top and bottom edges of cutout.

B=Allow 11/16"–3/4" for overlap of oven over side edges of cutout.

C=28-1/4" without trim and 28-3/4" with trim.

Conduit 

48-1/2" 

5

27-1/4'' MIN.
27-5/16'' MAX.
Cutout height

A

B

23-1/2'' MIN.

Cutout depth

22'' MIN.

CL

2 x 4 or

equivalent

runners

Suitable

bracing

to support

runners

21-5/8"

over centerline

of cabinet

(must support 275 lbs.)

Cutout width
28-1/2'' MIN.
28-5/8'' MAX.

29-3/4

C

30

Recommended 

cutout location 

32-1/2" 

from floor

21

Junction 

box

location

Allow minimum of 21'' for clearance

to adjacent corners, drawers, walls, or etc.
A=Allow 1" overlap of oven over top and bottom edges of cutout.

B=Allow 11/16"–3/4" for overlap of oven over side edges of cutout.

C=28-1/4" without trim and 28-3/4" with trim.

Conduit

(72" 

long)

5

27-1/4'' MIN.
27-5/16'' MAX.
Cutout height

A

B

23-1/2'' MIN.

Cutout depth

22'' MIN.

Dimensions and Installation Information (in inches)