Height to top of hinge (in.) 

A

69-1/4*

Height to top of case (in.) 

B

68-3/4

Case depth without door (in.) 

C

23-7/8

Case depth less door handle (in.) 

D

26-3/4

Case depth with door handle (in.) 

E

29-3/16

Depth with fresh food door open 90° (in.) 

F

45-9/16

Width (in.) 

G

35-3/4

Width with door open 90° inc. door handle (in.) 

H

40

Ai

Cl

ea

ra

nc

es

Each side (in.)

1/8

Top (in.)

1

Back (in.)

1/2

* Height to top of door trim (in.): 70-1/4 
† Water hook-up fits in back air clearance when calculating 

installation depth.

If installed against a wall, allow clearance of 13-15/16" on  
freezer side to remove bin. 
Clearance required to remove fresh food full-size pan without 
disassembling is 18-5/8".
Allow additional space for any necessary leveling adjustments.

Specification Created 2/07

Dimensions and Installation Information (in inches) 

210253

"94 SxS Refer

A

Front View

Top View

G

D

C

F

B

E

H

PSI23MGW 

GE Profile

 Counter-Depth

 

23.3 Cu. Ft. Side-By-Side Refrigerator

Summary of Contents for Profile PSI23MGW

Page 1: ...idth with door open 90 inc door handle in H 40 Air Clearances Each side in 1 8 Top in 1 Back in 1 2 Height to top of door trim in 70 1 4 Water hook up fits in back air clearance when calculating installation depth If installed against a wall allow clearance of 13 15 16 on freezer side to remove bin Clearance required to remove fresh food full size pan without disassembling is 18 5 8 Allow addition...

Page 2: ...binet 25 Counter Top Electrical Water Trim 3 4 Airspace 1 2 Gap 1 4 Wall Plates 24 Cabinet FOR 21 CUBIC FOOT MODELS FOR 24 CUBIC FOOT MODELS Fig 2A eps Installation Tips to Maximize the Built In Look All wall floor molding should be removed prior to installation Water recess on rear wall recommended to prevent water line damage 48 minimum length 1 4 diameter water line tubing recommended When poss...

Page 3: ...m of 36 1 8 is required for refrigerator installation with collar Be sure to allow for 1 2 or 3 4 side panels in addition to the 36 1 8 minimum Typical Installation Shaded areas represent front surfaces of side panels and overhead cabinet or soffit that contacts trim Refer collar trim install 70 1 4 36 1 8 24 1 2 1 2 minimum The rough in dimension of 70 1 4 is minimum and is measured from the fini...

Page 4: ...FRONT FRONT Alternate water line location through floor 1 2 Water hook up on the refrigerator Recommended water line location using recess in rear wall Recommended single loop of 1 4 copper water line Water hook up on the refrigerator Rear Wall View 18 24 Allow 48 minimum water line to enable refrigerator to be pulled forward Alternate water line location through floor 1 2 Recommended water line l...

Page 5: ... cabinet providing easy loading and unloading Quick Ice Option Makes ice up to 50 faster than normal settings ideal for entertaining TurboCool Setting Revs up the refrigerator cooling it quickly after frequent door openings Integrated Ice System Frees up valuable freezer space It tilts down providing easy access to bulk ice Tilt Out Freezer Door Bins Move forward for convenient access Integrated S...

Reviews: