GE Profile JVB37HBB Owner'S Manual & Installation Instructions Download Page 1

V

en

t Systems

959-0445-000    

49-80381    12-05 JR   

JVB37
JVB67
JVB94
JVB98

Owner’s Manual

& Installation

Instructions

ge.com

Downdraft

Write the model and serial 
numbers here:

Model # ______________________

Serial # ______________________

You can find them on a label on
the side of the blower housing.

Safety Instructions

 . . . . . . .2, 3, 7

Operating Instructions

Cooking Tips  . . . . . . . . . . . . . . . .5
Raise/Lower Switch . . . . . . . . . . .4
Using the Cooktop  . . . . . . . . . . .4
Using the Downdraft System  . . .4

Care and Cleaning

Grease Filters  . . . . . . . . . . . . . . . .5
Painted or Metal Surfaces . . . . . .5
Stainless Steel Surfaces  . . . . . . . .5

Installation Instructions

Advance Planning  . . . . . . . . . .8, 9
Before You Begin . . . . . . . . . . . . .6
30

″ 

Cooktop/Downdraft 

Units JVB37 and JVB94 . . . . . . .10
36

″ 

Cooktop/Downdraft 

Units JVB67 and JVB98 . . . . . . .11
Dimensions and Clearances  . .7, 8
Ductwork  . . . . . . . . . . . . .8, 13, 15
Electrical and Gas Location  . . . .8
Installation Possibilities  . . . . . . . .9
Installing the Downdraft 
Vent System  . . . . . . . . . . . . .10–17
Optional Kits  . . . . . . . . . . . . . . .17
Power Supply  . . . . . . . . . . . . . . .12
Raise/Lower Switch . . . . . . . . . .16
Venting Options  . . . . . . . . . . . .14

Troubleshooting Tips

 . . . . . . .18

Consumer Support

Consumer Support . . . . . . . . . .20
Warranty . . . . . . . . . . . . . . . . . . .19

Summary of Contents for Profile JVB37HBB

Page 1: ...Cooktop 4 Using the Downdraft System 4 Care and Cleaning Grease Filters 5 Painted or Metal Surfaces 5 Stainless Steel Surfaces 5 Installation Instructions Advance Planning 8 9 Before You Begin 6 30 Co...

Page 2: ...re servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means canno...

Page 3: ...led 4 You can fight the fire with your back to an exit Based on Kitchen Fire safety Tips published by NFPA CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materia...

Page 4: ...of the switch and hold until you observe the vent moving then release The air vent will rise Use the selector switch to turn the blower ON OFF or to change the blower speed The vent may be lowered by...

Page 5: ...rners Canning When canning foods in a water bath canner a gentle but steady boil must be maintained continuously for the required time When canning foods in a pressure canner the pressure must be main...

Page 6: ...cal inspector s use IMPORTANT Observe all governing codes and ordinances Note to Installer Be sure to leave these instructions with the Consumer Note to Consumer Keep these instructions for future ref...

Page 7: ...or ceiling do not damage electrical wiring and other hidden utilities WARNING To reduce the risk of fire use only metal ductwork C B A IMPORTANT These vents are recommended for island installations Ag...

Page 8: ...placing cabinetry directly above the cooking surface when possible If cabinetry is used above the cooking surface Installation must conform with local codes Use cabinets no more than 13 deep Maintain...

Page 9: ...Maintain cutout clearances to front edge as specified In an island or peninsula the countertop can be extra deep to provide seating opposite of the cooktop Adding base cabinets on each side of the coo...

Page 10: ...Surface Depth Minimum Setback Combined Combined Model No Width Overall Depth with Downdraft Cutout to Front Edge Cutout Width Cutout Depth JP326 30 1 4 21 1 4 23 3 8 2 1 2 28 1 2 22 3 8 JP340 JP350 2...

Page 11: ...21 1 4 23 1 8 2 1 2 34 22 7 8 JGP962 36 20 7 16 22 9 16 2 1 2 34 21 3 4 JGP962S 36 1 8 21 1 16 23 3 16 2 1 2 34 22 1 8 Includes 1 8 gap between cooktop and vent trim Required to maintain UL or AGA ap...

Page 12: ...tric cooktop the vent must operate from a separate 120V outlet A properly grounded 3 prong receptacle should be located within reach of the vents 2 foot power cord Locate the receptacle inside the cab...

Page 13: ...Pieces Length Pieces Length Pieces Length 31 4 x 10 to 6 Round 6 Round 1 ft per 31 4 x 10 Transition 12 ft Straight foot length 45 Elbow 5 ft 90 Elbow 6 Round 31 4 x 10 1 ft per 31 4 x 10 Wall Cap 21...

Page 14: ...ng plate assembly Retain screws Remove the blower assembly turn it over to access the 4 nuts holding the blower to the mounting plate Remove the nuts IMPORTANT Do not lift the motor by the power cable...

Page 15: ...wndraft unit slots INTO the next piece of the duct Secure the joints with self tapping screws and apply duct tape around the joints to ensure an airtight seal 2 INSTALL THE DOWNDRAFT VENT Place the do...

Page 16: ...ead through the mounting bracket and countertop Press trim over the mounting bracket to set the adhesive Connect Raise Lower Wire Lead to Wire Box Thread wire end with the connector through the hole o...

Page 17: ...touches the front edge of the downdraft cover Using a dime as a thickness gauge align the cooktop so that there is a minimum uniform gap of 0 05 the thickness of a dime between the cooktop and the do...

Page 18: ...extended Press the Raise Lower switch The blower control switch Slide it to the right may be in the OFF position Vent does not rise Vent not plugged into an outlet Plug vent into a 120V power outlet R...

Page 19: ...o have other rights which vary from state to state To know what your legal rights are consult your local or state consumer affairs office or your state s Attorney General If you have an installation p...

Page 20: ...warranty and learn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer H...

Page 21: ...y limpieza Filtros para grasa 5 Superficies de acero inoxidable 5 Superficies pintadas o met licas 5 Instrucciones de instalaci n Antes de empezar 6 Conductos 8 13 15 Dimensiones y espacios 7 8 Insta...

Page 22: ...ad apague la corriente en el panel de servicio y bloquee el medio de desconexi n del servicio para evitar que la corriente se encienda de manera accidental Cuando no se pueda bloquear el medio de desc...

Page 23: ...a cocina publicado por NFPA PRECAUCI N sese para fines de ventilaci n general nicamente No lo utilice para ventilar materiales y vapores peligrosos o explosivos Cerci rese de que todos los dedos est n...

Page 24: ...or y sostenga hasta que observe la unidad est en movimiento luego libere El sistema de ventilaci n de aire se levantar Use el interruptor selector para encender ON apagar OFF o cambiar la velocidad de...

Page 25: ...vas Al preparar conservas de alimentos en una olla de preparaci n de conservas canner con ba o de agua se debe mantener un hervor leve pero constante por el tiempo necesario Al preparar conservas en u...

Page 26: ...os y ordenanzas vigentes Nota para el instalador Cerci rese de dejar estas instrucciones en poder del consumidor Nota para el consumidor Mantenga estas instrucciones para referencia futura Nota Es nec...

Page 27: ...u otros cables ocultos de servicios p blicos ADVERTENCIA Para reducir el riesgo de incendio use nicamente conductos de metal C B A IMPORTANTE Este sistema de ventilaci n est recomendado para la instal...

Page 28: ...le evite colocar gabinetes directamente encima de la superficie de la estufa Si usa gabinetes encima de la superficie de la estufa La instalaci n debe cumplir con los c digos locales Use gabinetes no...

Page 29: ...forma especificada En un dise o tipo isla o pen nsula la encimera puede tener profundidad adicional para ofrecer la posibilidad de sentarse frente a la estufa Agregar gabinetes de base en cada lado de...

Page 30: ...Profundidad total superficie con la Corte de retracci n Ancho de la superficie unidad de m nimo hasta el Ancho de corte Profundidad de Modelo No total de la estufa tiro descendente borde delantero com...

Page 31: ...escendente Preparaci n del corte Profundidad de la Profundidad total superficie con la Corte de retracci n Ancho de la superficie unidad de tiro m nimo hasta Ancho de corte Profundidad de Modelo No to...

Page 32: ...lador se debe operar en una tomacorriente independiente de 120V Se debe ubicar un tomacorriente de tres patas correctamente conectado a tierra dentro del alcance del cable el ctrico de 2 pies de la un...

Page 33: ...cm 3 66 ms Tapa de pared Tubo recto 1 pie 30 cm Codo plano de circular de 6 de 31 4 x 10 por longitud 90 de 31 4 x 10 24 pies 15 cm con 21 pies 8 cm x 25 cm en pies 8 cm x 25 cm 7 32 ms regulador de t...

Page 34: ...ornillos Retire la ensambladura del ventilador volt ela para tener acceso a las 4 tuercas que sostienen el ventilador con el plato de montaje Retire las tuercas IMPORTANTE No levante el motor por el c...

Page 35: ...empates con tornillos auto enrroscantes y aplique cinta de conductos alrededor de los empates para garantizar un sellamiento herm tico 2 INSTALE EL VENTILADOR DE TIRO DESCENDENTE Coloque el ventilador...

Page 36: ...te de montaje y la encimera Presione la montura sobre el soporte de montaje para fijar el adhesivo Conecte el cable del interruptor Raise Lower a la caja de cables Pase el extremo del cable con el con...

Page 37: ...tero de la tapa del sistema de tiro descendente Con una moneda para medir el espesor alinee la estufa de manera que haya un espacio m nimo uniforme de 0 05 el espesor de una moneda de 10 centavos entr...

Page 38: ...Desl celo a la derecha del ventilador puede estar la posici n de apagado OFF La unidad no se levanta La unidad no est conectada Conecte la unidad a una tomacorriente de 120V a la corriente El interrup...

Page 39: ...conocer sus derechos legales consulte con su oficina local o estatal de asuntos del consumidor o con el procurador general de su estado Si tiene un problema con la instalaci n p ngase en contacto con...

Page 40: ...detalles sobre descuentos especiales disponibles mientras su garant a est a n activa Puede comprarla en l nea en cualquier momento o llamar al 800 626 2224 durante horas normales de oficina GE Consum...

Reviews: