background image

TM

JS998SH/TH/KH/BH – GE Profile™ 30" Slide-In Electric Range with Trivection™ Technology

Dimensions (in inches)

Note

: Cabinets installed adjacent to slide-in electric ranges must have an  

adhesion spec of at least 194°F temperature rating.

Note

: All 30" Slide-In Ranges conform to U.L. requirements for 0" spacing from range 

to adjacent walls below countertop. To reduce possibility of scorching the side walls 

above the countertop when no load is present on burners, it is recommended that a 

minimum 6" spacing from adjacent side wall be allowed for possible extended high-

heat element operation.

Receptacle Locations:

 For all 30" Slide-In Ranges locally approved flexible service 

cord or conduit must be used because terminals are not accessible after range 

installation. See shaded area in drawing for location of electrical outlet box. Recom-

mended outlet locations allow range to be installed directly against rear wall.

Accessory Backguards

(Attaches to the back of range as a backguard when unit is installed in  

30" free-standing cutout)

JXS37WW – White

JXS37CC – Bisque

JXS37BB – Black/Stainless

Installation Information:

 Before installing, consult installation instructions 

packed with product for current dimensional data.

 

 

KW Rating

  240V

 

12.8

 

208V

 

9.6

Breaker Size

  240V

 

40 Amps

 

208V

 

40 Amps

For answers to your Monogram,® GE Profile™ or 

GE® appliance questions, visit our website at

GEAppliances.com or call  

GE Answer Center® service, 800.626.2000.

Specification Revised 7/05

220450

All GE ranges are equipped with 

an Anti-Tip device. The installation 

of this device is an important, 

required step in the installation  

of the range.

Acceptable

Electrical

Outlet Area

30" Min.

30" Min.

Shave Raised Edge To Clear

31-1/8" Wide Control Panel

2000_slide_in.eps

2-7/8" 

To Front  

Surface Of  

Countertop

20-5/8" Door  

Clearance

From Front  

Surface of  

Countertop

31-1/4

30

27-1/2

36

Recommended

6" Min.

From Walls

23-3/16

15" Min.

A/B

13" Max.

2-1/2

30

25

9/16

7-1/2

2-1/2

Accessory 

Backguard

24

Acceptable

Electrical

Outlet Area

30" Min.

30" Min.

Shave Raised Edge To Clear

31-1/8" Wide Control Panel

2000_slide_in.eps

2-7/8" 

To Front  

Surface Of  

Countertop

20-5/8" Door  

Clearance

From Front  

Surface of  

Countertop

31-1/4

30

27-1/2

36

Recommended

6" Min.

From Walls

23-3/16

15" Min.

A/B

13" Max.

2-1/2

30

25

9/16

7-1/2

2-1/2

Accessory 

Backguard

24

R

Listed by 

Underwriters 

Laboratories

28-1/4*

36

Maintain 

at least 6" 

from nearest 

combustible 

surface.

Acceptable

Electrical

Outlet Area

30" Slide-In Range 

Dimensions (in inches)

45-1/8

2-1/4

5

6

4-1/2

30

30 Min.

15 Min.

6

30" Slide-in Elec. Range 

Aug. 8, 2003 -km

23-3/16

30

30

If you are NOT using the

Filler strip or Backguard:

If you are using the

Filler strip or Backguard:

25

*Wall to front of 

 closed door handle  

 on model JSP34.

 28" on models 

 JSP26/JSS26/16.

Note: Range may be placed with 0" clearance (flush) at the back wall and side walls 

below countertop if the range side trims above the countertop extend beyond the cabinet 

fronts at least 1/4". (Self-clean models only.) Maintain at least 6" distance from nearest 

combustible surface.    

30

31-1/2

28-1/4*

36

Maintain 

at least 6" 

from nearest 

combustible 

surface.

Acceptable

Electrical

Outlet Area

30" Slide-In Range 

Dimensions (in inches)

45-1/8

2-1/4

5

6

4-1/2

30

30 Min.

15 Min.

6

30" Slide-in Elec. Range 

Aug. 8, 2003 -km

23-3/16

30

30

If you are NOT using the

Filler strip or Backguard:

If you are using the

Filler strip or Backguard:

25

*Wall to front of 

 closed door handle  

 on model JSP34.

 28" on models 

 JSP26/JSS26/16.

Note: Range may be placed with 0" clearance (flush) at the back wall and side walls 

below countertop if the range side trims above the countertop extend beyond the cabinet 

fronts at least 1/4". (Self-clean models only.) Maintain at least 6" distance from nearest 

combustible surface.    

30

31-1/2

Reviews: