Family Catalog
Type
Enclosure Output
No. of
Connectors
Single Phase
Integrated
Meter
RFID
Cat #
Single
Pedestal
NEMA 3R
208-240V 30A 1
phase
1
Yes
No
EVSN3
Yes
EVSRN3
Double
Pedestal
NEMA 3R
208-240V 30A 1
phase
2
Yes
No
EVDN3
Yes
EVDRN3
Pole
NEMA 3R
208-240V 30A 1
phase
1
Yes
No
EVPN3
Yes
EVPRN3
Wall
NEMA 3R
208-240V 30A 1
phase
1
Yes
No
EVWN3
Yes
EVWRN3
- Table 11 -
3.4
Additional Considerations
Physical Security
Physical security is a necessary consideration in any installation of this type. There should be physical
controls to reduce the probability of a malicious entity’s chances of gaining access to any area of the
system. Network, maintenance access and power connections should be secured with strong
physical controls, i.e. all connections behind an access panel or door with a keyed lock to limit access.
This door or access panel should be strong (metal as a suggestion) and the lock should be of a type
that is not commonly available to the general public.
All wiring should be enclosed in conduit meeting the local electrical and communications building
codes. And all conduits should firmly attach to the secured “box” where communications would be
terminated within the Charging Station.
3.5
EVSE Controller Settings
3.5.1
Configuration Switch Settings
Using the configuration dip-switch S6, the controller can be placed into the desired operational mode.