GE Multilin
G60 Generator Protection System
D-1
APPENDIX D
D.1 IEC 60870-5-104
D
APPENDIX D IEC 60870-5-104 COMMUNICATIONSD.1IEC 60870-5-104
D.1.1 INTEROPERABILITY DOCUMENT
This document is adapted from the IEC 60870-5-104 standard. For this section the boxes indicate the following:
– used
in standard direction;
– not used;
– cannot be selected in IEC 60870-5-104 standard.
1.
SYSTEM OR DEVICE:
System Definition
Controlling Station Definition (Master)
Controlled Station Definition (Slave)
2.
NETWORK CONFIGURATION:
Point-to-Point
Multipoint
Multiple Point-to-Point
Multipoint Star
3.
PHYSICAL LAYER
Transmission Speed (control direction):
Transmission Speed (monitor direction):
4.
LINK LAYER
Unbalanced Interchange
Circuit V.24/V.28 Standard:
Unbalanced Interchange
Circuit V.24/V.28 Recommended
if >1200 bits/s:
Balanced Interchange Circuit
X.24/X.27:
100 bits/sec.
200 bits/sec.
300 bits/sec.
600 bits/sec.
1200 bits/sec.
2400 bits/sec.
4800 bits/sec.
9600 bits/sec.
2400 bits/sec.
4800 bits/sec.
9600 bits/sec.
19200 bits/sec.
38400 bits/sec.
56000 bits/sec.
64000 bits/sec.
Unbalanced Interchange
Circuit V.24/V.28 Standard:
Unbalanced Interchange
Circuit V.24/V.28 Recommended
if >1200 bits/s:
Balanced Interchange Circuit
X.24/X.27:
100 bits/sec.
200 bits/sec.
300 bits/sec.
600 bits/sec.
1200 bits/sec.
2400 bits/sec.
4800 bits/sec.
9600 bits/sec.
2400 bits/sec.
4800 bits/sec.
9600 bits/sec.
19200 bits/sec.
38400 bits/sec.
56000 bits/sec.
64000 bits/sec.
Link Transmission Procedure:
Address Field of the Link:
Balanced Transmission
Unbalanced Transmission
Not Present (Balanced Transmission Only)
One Octet
Two Octets
Structured
Unstructured
Frame Length (maximum length, number of octets): Not selectable in companion IEC 60870-5-104 standard
Summary of Contents for Multilin g60
Page 10: ...x G60 Generator Protection System GE Multilin TABLE OF CONTENTS INDEX ...
Page 32: ...1 22 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 160: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 486: ...5 326 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 518: ...6 32 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 532: ...7 14 G60 Generator Protection System GE Multilin 7 2 TARGETS 7 COMMANDS AND TARGETS 7 ...
Page 748: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIX D D ...
Page 760: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIX E E ...