CHAPTER 2: INSTALLATION
ELECTRICAL INSTALLATION
850 FEEDER PROTECTION SYSTEM – INSTRUCTION MANUAL
2–15
Figure 2-18: Typical wiring diagram – 850-D
DIRECTION OF POWER FLOW FOR POSITIVE W
A
TTS
POSITIVE DIRECTION OF LAGGING V
ARS
D9
CO
M
+24 V
F21
N
N
INSTRUCTION MANUAL
SEE VT WIRING IN
CONNECTION
WYE VT
INSTRUCTION MANUAL
INPUT WIRING IN
SEE GROUND
850-D Distribution Feeder
Protection System
J9 J10 J11 J12 J13 J14
OPEN DELTA VT CONNECTION
N
N
A
I
G
I
sg
I
C
I
N
B
I
GROUND
PHASE
A
PHASE B PHASE C
CAN
10
D8
D
D7
4
5
C
V
B
V
A
V
X
V
X
V
C
V
B
V
A
V
COMPUTER
PERSONAL
COMMUNICATIONS
D1 D2 D3 D
D
D6
SLOT J
POWER
CONTROL
RS485
COMMUNICATIONS
IRIG-B
PROGRAMMING PORT]
[FRONT PANEL LOCAL
[BACK PANEL ETHERNET PORT RJ45 OR ST]
SLOT F: I/O_A (OPTIONAL)
VOL
T
AGE INPUTS
CURRENT
INPUTS
ETHERNET
COMPUTER
PERSONAL
USB
PWR SUPPLY
STUD
GND
BUS
GROUND
BUS
COMMON
DIGITAL INPUT 7
DIGITAL INPUT 6
DIGITAL INPUT 5
DIGITAL INPUT 4
DIGITAL INPUT 3
DIGITAL INPUT 2
DIGITAL INPUT 1
F20
F19
F18
F17
F16
F15
F14
F13
J16
D
N
U
O
R
G
L
A
R
T
U
E
N
E
NI
L
A1
A2
A3
J14
J13
J12
J11
J10
J9
ACCESS POINT
J15
AUX
VT
G1
G2
G3
G4
G5
G6
G7
G8
G9
G10
G11 G12 G13 G14 G15 G16 G17 G18 G19 G20 G21 G22 G23 G24
DCmA I/O
ANALOG OUTPUT
ANALOG INPUT
RTD
1
1
2
3
4
5
6
7
1
1
2
3
4
SHIELD
SHIELD
SHIELD
RETURN
HOT
COMP
RETURN
RETURN
ANY MEASURED
OR METERED
ANALOG PARAMETER
OUTPUTS
AMBIENT
TEMPERATURE
RESERVED
+
+
+
+
+
+
+
+
+
+
+
H9
DIGIT
AL
INPUT
7
DIGIT
AL
INPUT
6
DIGIT
AL
INPUT
5
DIGIT
AL
INPUT
4
DIGIT
AL
INPUT
3
DIGIT
AL
INPUT
2
DIGIT
AL
INPUT
1
S
T
U
P
N
I
L
A
T
I
G
I
D
H8
H7
H6
H5
H4
H3
H2
H1
+24 V
H12
COMMON
DIGIT
AL
INPUT
10
H1
1
H10
DIGIT
AL
INPUT
9
DIGIT
AL
INPUT
8
SLOT G: I/O_L (OPTIONAL)
CH1
CH4
CH3
CH2
FIBER INPUT
1
ARC FLASH
FIBER INPUT
2
FIBER INPUT
3
FIBER INPUT
4
SLOT H: I/O_F (OPTIONAL)
C9
C8
C7
C6
C5
C4
C3
C2
C1
C12
C11
C10
C15
C14
C13
C18
C17
C16
DIGITAL INPUT 8
DIGITAL INPUT 7
DIGITAL INPUT 6
COMMON
DIGITAL INPUT 5
DIGITAL INPUT 4
DIGITAL INPUT 3
DIGITAL INPUT 2
DIGITAL INPUT 1
DIGITAL INPUT 13
COMMON
DIGITAL INPUT 15
DIGITAL INPUT 14
DIGITAL INPUT 12
DIGITAL INPUT 11
COMMON
DIGITAL INPUT 10
DIGITAL INPUT 9
B9
B8
B7
B6
B5
B4
B3
B2
B1
B12
B11
B10
B15
B14
B13
B18
B17
B16
SHIELD
RETURN
COMP
HOT
COMP
HOT
RETURN
COMP
HOT
HOT
RESERVED
SHIELD
COMP
RETURN
COMP
HOT
COMP
HOT
RTD 1
RTD 1/2
RTD 2
RTD 3
RTD 4
RTD 5
RTD 6
RTD 3/4
RTD 5/6
SLOTS B AND C:
6 RTDs (I/O_R OR I/O_S*)
OR 15 DIGITAL INPUTS (I/O_C)
* SUPPORTS 10 OHM COPPER RTD AS WELL
ANY MEASURED OR
METERED ANALOG PARAMETER
INPUTS
CABLE SHIELD TO BE GROUNDED
AT PLC/COMPUTER END ONLY
RTD
RTD
*
*
* AVAILABLE WITH SENSITIVE
GROUND ONLY
FIBER/COPPER
ETHERNET
COPPER
ETHERNET
Front Panel
TYPE B
USB
SLOT D
SLOT E
Rear Panel
APPLICABLE FOR
COMMUNICATION
OPTION ‘SE’ ONLY
(OP-
TIONAL)
RJ45
ST/RJ45
ST/RJ45
RESERVED
RESERVED
RESERVED
RESERVED
SLOT A
DIGIT
AL INPUTS
THRESHOLD
SETTING
GROUP 1
THRESHOLD
SETTING
GROUP 2
THRESHOLD
SETTING
GROUP 3
PHASE CTs
52b
52a
COIL
CLOSE
COIL
TRIP
CIRCUIT
CLOSE
CIRCUIT
TRIP
MANUAL
IN INSTRUCTION
MONITORING
CLOSE COIL
SEE TRIP AND
CONTROL POWER
SHOWN WITH NO
OUTPUT CONTACTS
F2
F1
V
V
F24
F23
F22
F12
F11
F10
F9
F8
F7
F6
F5
F4
F3
RELAY
FAILURE
CRITICAL
AUXILIARY 3
CLOSE
TRIP
AUXILIARY 4
A2
A2
OUTPUT REL
A
Y
S
SLOT K
52
LOAD
INSTRUCTION MANUAL
INPUT WIRING IN
SEE GROUND
GROUND
PHASE
A
PHASE B PHASE C
VOL
T
AGE INPUTS
CURRENT
INPUTS
* AVAILABLE WITH SENSITIVE
GROUND ONLY
52
LOAD
DIRECTION OF POWER FLOW FOR POSITIVE W
A
TTS
POSITIVE DIRECTION OF LAGGING V
ARS
J1
J2
J3
J4
J5
J6
J7
J8
J7
J8
*
*
K1
K2
K3
K4
K5
K6
K7
K8
K7
K8
N
N
N
N
A
I
G
I
sg
I
C
I
N
B
I
C
V
B
V
A
V
C
V
B
V
A
V
K14
K13
K12
K11
K10
K9
PHASE CTs
D9
CAN
RMIO
10
D8
D
CABLE SHIELD TO BE GROUNDED
AT PLC/COMPUTER END ONLY
COM
**SLOT D OPTIONAL RMIO
D8 is Ground ( )
A +
B -
COM
RMIO
RESRVD
CO
M
Summary of Contents for Multilin 850
Page 10: ...VIII 850 FEEDER PROTECTION SYSTEM INSTRUCTION MANUAL ...
Page 135: ...CHAPTER 3 INTERFACES SOFTWARE INTERFACE 850 FEEDER PROTECTION SYSTEM INSTRUCTION MANUAL 3 41 ...
Page 151: ...CHAPTER 3 INTERFACES SOFTWARE INTERFACE 850 FEEDER PROTECTION SYSTEM INSTRUCTION MANUAL 3 57 ...
Page 153: ...CHAPTER 3 INTERFACES SOFTWARE INTERFACE 850 FEEDER PROTECTION SYSTEM INSTRUCTION MANUAL 3 59 ...
Page 439: ...CHAPTER 7 MONITORING FUNCTIONS 850 FEEDER PROTECTION SYSTEM INSTRUCTION MANUAL 7 19 ...
Page 644: ...11 20 850 FEEDER PROTECTION SYSTEM INSTRUCTION MANUAL FLEXELEMENTS CHAPTER 11 METERING ...