8–84
850 FEEDER PROTECTION SYSTEM – INSTRUCTION MANUAL
AUTORECLOSE
CHAPTER 8: CONTROL
IN PROGRESS OUTPUT RELAY X
For details see
Selects the relays required to operate while Autoreclosure is in progress. The selected
relays operate while the front panel ‘Reclosure in Progress’ indicator is on. This indication
is on when Autoreclose has been initiated, but the breaker is not closed and Autoreclose
isn’t blocked. This output can be used to block the operation of a transformer tap
changer during a Reclose sequence.
LOCKOUT OUTPUT RELAY X
For details see
Selects the relays required to operate when Autoreclose scheme goes to Lockout. No
further circuit breaker closure is initiated until the Autoreclose Lockout is Reset. The
selected relays operate while the front panel Reclosure Lockout indicator is on.
EVENTS
Range: Disabled, Enabled
Default: Enabled