background image

Monogram.

For answers to your Monogram,

® 

GE Profile

or 

GE appliance questions, visit our website at
GEAppliances.com or call 
GE Answer Center

®

service, 800.626.2000.

R

Listed by
Underwriters
Laboratories

Specification Revised 2/02

ZISS420NMSS - GE Monogram 42" Built-In Stainless Steel Refrigerator with 

Automatic Icemaker and Water Filter

41-1/2

7"

5"

Electrical
Area

84 1/2" max

83 1/2" min

Finished
Opening

74" From Floor

to Bottom

of Electrical

24"

5"

5"

3 1/2"

Water Supply

3 1/2"

42" Models 18"

THE INSTALLATION SPACE

Product Clearances

These refrigerators are equipped with a 2 position door
stop. The factory set 130° door swing can be adjusted 
to 90° if clearance to adjacent cabinets or walls 
is restricted.

19"

13"

23-7/8"
Behind
Frame

26-5/8"

Allow minimum clearances for freezer door  and
fresh food door for a full 130° door swing and to
allow for pan removal.

4" minimum clearance is required when door
swing is adjusted to 90°. If the 90° door stop
position is used, pan access is maintained, but
pan removal is restricted.

130° Door Swing

90° Door Swing

Water And Electrical Locations 

The opening must be prepared with the electrical and water
supply located as shown.

The cutout depth must be 24".

Designed for industry standard flush installation. The
refrigerator will project forward, slightly beyond adjacent
cabinetry, depending on your installation.

The cutout depth beneath a soffit:

When installed beneath a soffit, the soffit cannot exceed the
24” installation depth shown. The top case trim overlaps the
bottom of the soffit.

Frameless cabinets:

The case trim overlaps cabinets at the top and sides.
Therefore, frameless cabinets may require filler strips to
prevent interference with cabinet door swing. The opening
must allow for filler strips.

Additional Specifications

• A 115 volt 60Hz., 15 or 20 amp power supply is required. An
individual properly grounded branch circuit or circuit breaker
is recommended. Install a properly grounded 3-prong electrical
receptacle recessed into the back wall. Electrical must be
located on rear wall as shown.

Note

: GFI (ground fault interrupter) is not recommended.

• Water line can enter the opening through the floor or back
wall. The water line should be 1/4" O.D. copper tubing between
the cold water line and 
water connection location, long enough to extend 
to the front of the refrigerator. Installation of an easily
accessible shut off valve in the water line is recommended.

*84" From
Floor to
Top Frame

42"

Frame to Frame

41"

Case Width

*83-1/2" 

at

Rear

* Shipping height.
The refrigerator
can be adjusted to
fit into a cutout that
is 83-1/2” min. to
84-1/2” max. height
Note that the top
case trim at the
front is 1/2” higher
and will overlap
upper cabinetry or
soffit. Use leveling
legs and wheels for
height adjustment.