background image

g

 

Product Data Sheet – rev 4.2 
July 4th 2003  
Page 3 
 
 

 

LightSpeed

16

 

 

With Xtream 

CT Scanner System 

GE Medical Systems-America 
Milwaukee, USA  - Fax: 1 414 544 3384 
GE Medical Systems-Asia: 
Tokyo, Japan - Fax: 81 425 85 5490 
Hong Kong - Fax: 852 2559 3588 
GE Medical Systems-Europe 

changes to be easily made, with virtually no 
restrictions; 

• 

Enhanced 

multi-tasking

 allows operators to 

review more than one exam simultaneously, 
independently - even with AutoView and 
AutoFilm on/ 

• 

Operator console convenient to locate in 
suite. 

• 

Computer, image processor and image 
reconstruction hardware completely 
integrated in base of console - no 
separate computer cabinet to site; 

• 

Be as self-teaching as possible, and have 

on-line access to tutorials

 as needed. 

• 

BrightBox™

 dedicated controls for 

image next, prior, manual paging and 
trackball W/L helps make two person 
image review practical; 

One key element of this design is to combine 
some of the best features from several 
product families into one state-of-the art CT 
system.  For example, the LightSpeed

16

 CT 

Scanner combines: 

• 

Split table top allows unrestricted patient 
viewing while still supporting 2 large color 
monitors; 

• 

Up to four 512x512 images from four 
different exams can be viewed on a large 
1024 color display. 

• 

Front and back work surfaces can be set 
during installation within a range of 
vertical heights that help accommodate a 
variety of siting requirements - especially 
surrounding the height of the console 
relative to the window into the scanning 
suite. 

• 

SmartTools

 productivity software to 

automate every step of the examination, 
critical for ensuring the highest productivity 
and throughput possible with the  
LightSpeed

16

 CT Scanner; 

• 

SmartmA™

  User Interface - automatically 

optimizes mA to maintain constant image 
noise when collimation/detector 
configuration, scan mode, scan rotation 
speed, table speed, or image thickness 
changes.  It takes the guesswork out of 
setting scan technique when changing 
parameters (note: user must select initial 
Noise Index as well as maximum mA 
setting). Noise index enable 100% Image 
Quality reproducibity from one patient to 
another and from one user to another. 

• 

Large screen interface

 for controlling scan 

acquisition easily, with virtually everything at 
a single glance; 

• 

Work surface accommodates a large variety 
of working conditions and individual 
operator preferences. 

• 

Excellent simultaneity and 

multi-tasking

 

performance; 

• 

Wide work surface

 has room for papers, 

patient charts, logbooks or other 
peripheral devices; 

• 

Completely 

protocol-driven 

scan control 

with a dramatic reduction in number of 
screens; 

• 

Wide area also helps make two person 
operation more comfortable and 
practical; 

• 

Protocol Pro™

 protocol manager - provides 

operator control of automated features (like 
AutoFilm, AutoStore, and AutoTransfer) on 
per patient basis. 

• 

Highly flexible editing tools that allow easy 
tailoring of the exam to the patient; 

• 

All console components (monitors, 
keyboard, mouse and BrightBox) are 
free-standing and can be easily moved 
on the front work surface; 

• 

Large, 1024 color display; 

• 

Patient demographics and exam protocols 
can be preprogrammed in advance of 
patient arrival through the Schedule Patient 
feature. 

• 

Leading edge, 

real-time image processing

 

(MPR, MPVR, Volume Viewer*). 

• 

All surfaces made of high-impact resin 
that hides marks and are easy to clean. 

In summary

, primary benefits

 of Interactive 

CT on the  LightSpeed

16 

Scanner: 

• 

A preprogrammed selection of AutoView 
and Image Review Layouts allow simple 
customization of the image presentation to 
match the anatomical area of interest - 
without the complexity of free-form 
“windows”. 

• 

Direct network connection

 means a multi-

suite Ethernet card is not required for a 
gateway out of the suite - saving costs and 
simplifying installation. 

• 

natural scan control

 user interface 

• 

Dramatic reduction in the number of 
screens; only 2 screens to set up first 
scan and 1 screen for real-time 
monitoring while scanning; 

• 

Learning Solutions

 provides an on-line 

Operator manual detailing system operation 
via a multi-media CD-ROM player integrated 
into the front of the operator console. 
Learning Solutions can also be accessed on 
a stand alone PC providing flexibility and 
productivity for on demand learning of 
system operation 

• 

ImageWorks™

 provides instant access to 

advanced image processing features such 
as MIP, MPR, MPVR, Volume Viewer*, 
Advanced Vessel Analysis*, CT Perfusion 
2* and DentaScan*. 

• 

Easier and more 

flexible

 protocols 

• 

Much more flexible and 

intuitive graphic 

prescriptio

n process with a 1024 

Localizer; 

• 

View/Edit Wizard

 intuitively adjusts 

dependent parameters automatically in 
response to operator-initiated changes 
and highlights them for quick review; also 
alerts the operator to incompatible 
dependencies requiring operator 
intervention; 

• 

No waiting for network transfer or image 
retrieval from archive media. 

Advanced Tube & Generator 
Technology 

• 

Background filming allows use of the full 
screen for AutoView and image 
review/processing without interruption when 
auto or batch filming.  Special “one touch” 
controls provide on-screen viewing of 
camera progress during 

AutoFilm

 without 

disrupting other image processes in 
progress. 

 

• 

DynaPlan Plus

 full screen display 

illustrates scan status pictorially, with 
real-time feedback. 

• 

The Performix  X-ray tube, with 6.3 MHU of 
storage and 53.2 kW operation, provides 
increased helical performance with greater 
patient throughput and virtually no tube 
cooling. Advanced technology in the 
Performix tube includes a metal-ceramic 
frame for long life, a high-speed bearing for 
sub-second scanning, a high-efficiency 
motor to accelerate the large anode and 

• 

Large color screen 

• 

ProView™

 visualization algorithms 

available to enhance anatomical structures 
without additional image reconstruction 
time. 

• 

Extensive use of picture icons and color 
cues enhance ease of use; 

• 

Large on-screen controls and attractive 
color palette provide comfortable viewing 
over extended periods. 

* Option 

Summary of Contents for LightSpeed 16

Page 1: ...o provide an optimized workflow solution from acquisition to final report Lowest dose acquisition using SmartmA TM an automatic modulation technique and DLP display that tells the operator the dose before the scan starts HyperPlane TM reconstruction algorithm tackles the inherent issues with fast high pitch helical scanning by reducing helical artifacts and dose and optimizing the slice profile Cr...

Page 2: ... may allow you to reduce contrast media perform better thin slice CT angiography exams use thinner slices for most exams and perform longer helical exams without tube cooling delays Remote Gantry Tilt from the Operator s Console to increase exam speed including built in safety features to prevent accidental contact of the gantry with the patient CTDIw DLP Dose Length Product and Dose Efficiency di...

Page 3: ...exam to the patient All console components monitors keyboard mouse and BrightBox are free standing and can be easily moved on the front work surface Large 1024 color display Patient demographics and exam protocols can be preprogrammed in advance of patient arrival through the Schedule Patient feature Leading edge real time image processing MPR MPVR Volume Viewer All surfaces made of high impact re...

Page 4: ...ontinue with additional helical scans or a set of axial scans Helical 8 SLICE HELICAL MODES Table Speed mm rotation Slice Thick ness mm Pitch 0 625 1 0 875 1 1 35 1 1 675 1 1 25 6 25 8 75 13 5 16 75 2 5 6 25 12 5 8 75 17 5 13 5 27 0 16 75 33 5 3 75 6 25 12 5 8 75 17 5 13 5 27 0 16 75 33 5 5 6 25 12 5 8 75 17 5 13 5 27 0 16 75 33 5 7 5 6 25 12 5 8 75 17 5 13 5 27 0 16 75 33 5 10 6 25 12 5 8 75 17 5...

Page 5: ...16 slice recon mode Ten user defined regions Each region has one default protocol displayed with the anatomical selector for very fast access to most commonly used protocols Scan Speeds Full 360 rotational scans in 0 5 0 6 0 7 0 8 0 9 1 0 seconds Maximum image to image cycle time is 10 for prospective and retrospective image to image display This applies for 512 matrix any display FOV in AutoView ...

Page 6: ...413 Prospective Recon Operator may initiate full recons at any table location in increments of 1 10 the image thickness image thickness remains constant 0 5mm Retrospective Recon Operator may initiate full recons at any table location in 0 1 mm increments image thickness remains constant Retrospective Image Decomposition The operator has the option to retrospectively decompose the original raw dat...

Page 7: ...e increment Gantry display in 0 5 mm increments On 8 inch 20 cm CATPHAN phantom 5 mm 3 at 13 3 mGy 3 mm 3 at 37 2 mGy For each rotation of the gantry the LightSpeed 16 collects 16 rows of scan data There are five reconstruction modes available for creating images from the multi slice scan data 1i 2i 4i 8i and 16i By using 1i 2i 4i and 8i reconstruction modes scan data can be combined prior to imag...

Page 8: ...r to acquisition The operator can select different reconstruction algorithms and display fields of view for each reconstruction This frees the operator from sitting at the console and directly contributes to increased productivity Standard Scans On GE Performance phantom Scan Time ISD mA Scans Acquisition Time 1 sec 1 sec 440 18 45 0 35 1 27 1 1 400 24 55 0 47 1 49 1 1 360 32 68 1 03 2 15 1 1 340 ...

Page 9: ...aker microphone and volume controls CTDIvol expressed in mGy 100 mAs Three button mouse with mouse pad The ImageWorks desktop also provides a gateway for DICOM 3 0 image transactions either through a local area network or via DICOM formatted MOD media Head 18 4 mGy 100 mAs Body 9 3 mGy 100 mAs BrightBox trackball assembly Two wide work surfaces Scout Scans All these devices are free standing and c...

Page 10: ...removed from the prescription Scan recon control uses only 2 screens to set up first scan New Patient and Protocol View Edit Dose Computation Display CTDIvol CTDI volume DLP Dose Length Product and Dose Efficiency computation and display during scan prescription provides patient dose information to the operator Protocol View Edit A single full screen View Edit table allows fast and easy examinatio...

Page 11: ...lows full use of the image display monitor for AutoView and image review processing without interruption during AutoFilm Gray Scale Enhancement An AutoFilm Composer provides a simple programming interface for automated filming set up ProView visualization algorithms are available to enhance anatomical structures without additional reconstruction time Batch Filming is accomplished through a single ...

Page 12: ...is is the ultimate tool to assess and quantify vascular structures including stenosis analysis stent planning procedures post stenting or vascular surgery follow up protocol driven tools to perform quick flexible and accurate quantitative analysis of vascular anatomy provides maximum minimum and mean intraluminal diameter measurements provides cross sectional areas of true orthogonal sections of t...

Page 13: ... sec and 40 mm sec System Components Horizontal Range 170 cm Horizontal Scannable Range 170 cm metal free axial and 160 cm metal free helical Scout Gantry Image transfer time using either AdvantageNet or DICOM 3 0 protocols is approximately 0 1 second per 512 image on a 100baseT Network Horizontal Speed Up to 100 mm sec Advanced slip ring design continuously rotates generator tube detector and dat...

Page 14: ... disk drive Average time to replace tube 10 hours High Performance Drive 2GB DDR266 Dual Channel Memory with a throughput of 4 2GB sec 36 GB 3 5 inch form factor High Voltage Generation UltraSCSI interface Image Processor High frequency on board generator Continuous operation during scan Standard MOD drive Nvidia Quadro4 980XGL AGP 8X graphics with 128MB Memory Magnetic Optical Disk Drive 53 2 kW ...

Page 15: ...time and receive pull query and storage commitment push Siting Requirements Minimum Suite Size AdvantageNet GenesisNet point to point send receive and pull query no broadcast Overall Suite Compatible UPS options are available if desired 15 5 feet 4 74 m wide x 19 5 feet 5 96 m deep x 9 feet 2 75 m high InSite point to point Cooling Requirements TCP IP for system administration Recommended Suite Si...

Page 16: ...ight 1 887 74 1 Table Width 610 24 Length 5 050 199 Height 1 120 44 Power Distribution Unit Width 762 30 Depth 585 23 Height 1 270 50 Operator Console Width 1 238 48 7 Depth 1 288 50 7 Height 1 257 49 5 Warranty The published Company warranty in effect on the date of shipment shall apply The Company reserves the right to make changes All specifications are subject to change Regulatory Compliance T...

Page 17: ...4th 2003 Page 17 LightSpeed16 With Xtream CT Scanner System GE Medical Systems America Milwaukee USA Fax 1 414 544 3384 GE Medical Systems Asia Tokyo Japan Fax 81 425 85 5490 Hong Kong Fax 852 2559 3588 GE Medical Systems Europe Option ...

Page 18: ...htSpeed16 With Xtream CT Scanner System GE Medical Systems America Milwaukee USA Fax 1 414 544 3384 GE Medical Systems Asia Tokyo Japan Fax 81 425 85 5490 Hong Kong Fax 852 2559 3588 GE Medical Systems Europe Minimum Room Layout Typical Room Layout Option ...

Reviews: