background image

U0806

BEFORE YOU BEGIN

Instructions to your plumber: Install 1/2 inch stop cock (tap), located in the cabinetry or adjacent to, or if possible above 

fridge cavity. Not to be located in the fridge cavity.

The water line installation is not warranted by the refrigerator or icemaker manufacturer. Follow these recommendations 

carefully to minimise the risk of expensive water damage.

Water hammer (water banging in the pipes) in house plumbing can cause damage to refrigerator parts and lead to water 

leakage or flooding. Call a qualified plumber to correct water hammer before installing the water supply line to the 

refrigerator.

To prevent burns and product damage, do not hook up the water line to the hot water line.

If you use your refrigerator before connecting the water line, make sure the icemaker power switch is in the 

O (off)

 position.

Do not install the icemaker tubing in areas where temperatures fall below freezing.

When using any electrical device (such as a power drill) during installation, be sure the device is insulated or wired in a 

manner to prevent the hazard of electric shock.

All installations must be in accordance with local plumbing code requirements. Installation of the icemaker must be done 

by a qualified service technician.

  !

   WARNING! Connect to potable water supply only.

INSTALLING THE WATER LINE

* Not including top trim kit piece

* Installation of power and 
water outlets; if located in 
fridge cavity, please ensure 
they are above fridge 
height.

*A

B

C

D

PIG23NGSFKB 

PIG23NGSFBB

*1759 mm

908 mm

742 mm

1158 mm

DIMENSIONS

607 mm

including hinge

Overall width

Depth including door 

handle

Depth with fridge door 

open 90°

Cabinet depth with 

door 

removed

Side-by-side Fridge

SPECIFICATIONS

General Electric Profile Arctica

Model 23

DIMENSIONS AND SPECIFICATIONS (for Built-In Style models)

E

%

CM
#ABINET

7ATER

%LECTRICAL

MM!IRSPACE
MM'APMM
7ALL0LATES 

CM

#OUNTERTOP

/œÊLiÊVœ˜˜iVÌi`Ê>LœÛiÊvÀˆ`}iʅiˆ}…Ì

F

Overall height including

trim kit piece

F

1790 mm

EXCLUSIVE DISTRIBUTOR OF

9518 GEspecs PIG23.indd   1

21/8/06   11:52:36 AM

Summary of Contents for Kleenmaid Arctica 23

Page 1: ...freezing When using any electrical device such as a power drill during installation be sure the device is insulated or wired in a manner to prevent the hazard of electric shock All installations must be in accordance with local plumbing code requirements Installation of the icemaker must be done by a qualified service technician WARNING Connect to potable water supply only INSTALLING THE WATER LIN...

Page 2: ...t the end of the tubing into the water valve connection as far as possible While holding the tubing tighten the fitting Fasten the tubing into the clamp provided to hold it in a vertical position You may need to pry open the clamp One of the illustrations adjacent will look like the connection on your icemaker Reattach the access cover TURN THE WATER ON AND PLUG IN THE REFRIGERATOR Arrange the coi...

Page 3: ...IT CLEARANCES OF AT LEAST q CM FROM THE HANDLE SIDE FOR FINGERTIP CLEARANCE 0ANELS THICKER THAN q MM UP TO q MM MAXIMUM WILL REQUIRE THAT THE OUTER q MM OF PANEL PERIMETER BE NO THICKER THAN q MM 7EIGHT LIMITATIONS FOR CUSTOM PANELS RESH OOD LBS KG MAX REEZER OOR LBS KG MAX q MM AX 0ANELS q MM THICK OR LESS 0ANELS LESS THAN q MM THICK 7HEN INSTALLING WOOD PANELS LESS THAN q MM THICK YOU NEED TO CR...

Page 4: ...ANELS INSTALLATION INSTRUCTIONS Dimensions for Custom Panels REEZER 0ANEL 7ITH ISPENSER RESH OOD 0ANEL q MM b q CM b q CM b q CM q MM UT OUT 2 4 q MM b q CM q MM UT OUT b q CM 2 4 OM 7OOD 0ANELS P OF THE PANELS NEED TO BE CUT OUT OF THE PANELS 4RIM KITS REEZER 0ANEL 7ITHOUT ISPENSER REEZER 0ANEL 7ITH ISPENSER RESH OOD 0ANEL UT OUT q MM b q CM b q CM q MM 2 4 q MM b q CM b q CM b q CM q MM UT OUT 2...

Page 5: ... Ë aËÍ Íj Ë ß Ë jËÄÖÁjËÍ ÍËÍ j Í Ë wËj W Ë j Ëw ÍÄËÄ Ö ßËMj aËÍ jË Ë wËÍ j 0 Ë0Á ÄjÁÍËÍ jË ÁjjãjÁË j Ë aË ÁjÄ Ë aË j ÁjwÖ ßË ÖÄ ËÍ jËÍ ËwÁjjãjÁË j Ë ËÖ Í Ë ÍËÄ ajÄ Í ËÍ jËÄ ÍËMj aËÍ jËa ÁË a j Ë ÖÄ ËÍ jËw jÁ j Ë Áj Ö ÁjaËÝ Í ËÄ jËa ÁË j Ä Ë ËMj a Í jËajW Á Í ÁË j Ë j j ÍËw ÁËwÁjÄ Ëw aË j ÄjÁÍËÍ jË ÍÍ Ë ÁjjãjÁË j ÁjwÖ ßË ÖÄ ËÍ jË j Ë ËÖ Í Ë ÍËÄ ajÄË Í ËÍ j Ä ÍËMj aËÍ jËa ÁË a j Ë ÖÄ ËÍ jËw jÁË j Áj...

Page 6: ...ILM ON THE OUTSIDE OF THE 3IDE 4RIM UNTIL THE 3IDE 4RIM IS INSTALLED IT THE BOTTOM OF THE 3IDE 4RIM UNDER THE OTTOM 4RIM AS ILLUSTRATED OLD THE 3IDE 4RIM AGAINST THE FRONT FACE OF THE DECORATOR PANELS AND FIT THE 3IDE 4RIM UNDER THE 4OP 4RIM AKE SURE THE MAGNETICALLY ATTACHED 3IDE 4RIM IS FITTED CORRECTLY AND THAT YOU ARE SATISFIED WITH THE APPEARANCE OF ALL THE PARTS 3IDE 4RIM 3IDE 4RIM OTTOM 4RI...