Installation Information:

 Before installing, consult installation 

instructions packed with product for current dimensional data.

27" Built-In Single Oven Dimensions (in inches)

Specification Revised 7/05

320431

2" x 4" 

or equiv.

runners

B MIN.

C MIN.

Conduit 48-1/2" long

6015 Built-in Single Oven  

(Pub. 1-G003 pg. 107) April 28, 1993

32-1/2

D

10

A

Allow 3/4"

for overlap

over all edges

of cutout

Locate

junction box

either 5" MIN.

below cutout

floor or 44"

MIN. above 

cutout floor

Minimum

cutout location

from floor

(Minimum 15-5/8"

from floor when

installed below built-in

microwave oven)

E

G

F

20

Note: These ovens are 

not

 

approved for stackable or  

side-by-side installations.
Note: These ovens can be 

installed side-by-side with no 

less than 30" distance between 

center-to-center of each oven.

Note: 

Cabinets installed adjacent to wall ovens  

must have an adhesion spec of at least a 194°F  

temperature rating.

Note: 

For 27" built-in single ovens, if marks, 

blemishes or the cutout opening is visible  

above the installed oven, it may be necessary  

to add wood shims under the runners and front 

trim until the marks or openings are covered.

Cabinet 

 

27"

  A – Cabinet Width Required 

27" min.

  B – Minimum Cabinet Depth 

23-5/8"

  C – Opening Width 

25" min. - 25-1/4 max. 

  D – Opening Height  

27-5/8" min. - 28-1/8 max.

Oven

  E – Overall Depth 

23-5/8"

   

w/o trim 

28-1/4"

  F – Overall Height  with trim 

29"

  G – Overall Width 

26-5/8"

 

CL

Suitable

bracing 

to support

runners

18" 

Over centerline

of cabinet

2" x  4" or

equivalent

runners

(Must support 275 lbs.)

R

Listed by 

Underwriters 

Laboratories

For answers to your Monogram,® GE Profile™ or 

GE® appliance questions, visit our website at

GEAppliances.com or call  

GE Answer Center® service, 800.626.2000.

 

 

KW Rating

  240V

 

3.4

 

208V

 

2.6

Breaker Size

  240V

 

20 Amps

 

208V

 

20 Amps

Electric wall ovens are not approved for installation with a plug and receptacle. 

They must be hard wired in accordance with installation instructions.