TOP BURNER ORIFICES
The top burner orifices each have a series of marks engraved on the
tops of the orifices (I, II, III) to denote their location. The marks
appear on both the Natural and LP gas orifices. The location
indicated by the marks, is the same for both gases.
See BURNER OUTPUT RATING charts at right for locations.
LF & RF
1.65 mm
WB02X9841
LF & RF
.84 mm
WB02K0022
LR
1.44 mm
WB06K0094
LR
.73 mm
WB19K5000
Burner
Size
Part Number
L.P.
Natural
SMALLER ORIFICES FOR HIGHER ELEVATIONS
LF & RF
11,000 BTU
Blue / Magenta
LR
9,500 BTU
Blue / Brown
RR
5,000 BTU
Blue / Blue
Burner
BTU Rate
Color
LP ORIFICE COLOR ID
Paint color codes have been added to the
sides of the LP orifices to aid in identifying
the proper orifice location during conver-
sion.
CONVERSION & ORIFICES INFORMATION
– 12 –
Burner
BTU Rate
Orifice Size
LF, RF
12,000
1.68 mm (III)
LR
9,500
1.50 mm (II)
RR
5,000
1.07 mm (I)
BAKE
16,000
#47 (.0785")
BROIL
13,500
(.069")
NATURAL GAS with
4
" W.C.P.
BURNER OUTPUT RATINGS; BTU/HR
175
III
Natural gas surface
orifices are marked
on top as shown
N
Burner
BTU Rate
Orifice Size
LF, RF
11,000
.94L mm (III)
LR
9,500
.89L mm (II)
RR
5,000
.63L MM (I)
BAKE
16,000
#56 (.0465")
BROIL
12,000
#59 (.041")
LP (PROPANE) GAS with 10" W.C.P.
BURNER OUTPUT RATINGS; BTU/HR
III
90
LP gas surface
orifices are marked
on top as shown
L
Air Adjustment
Shutter
Loosen
Air Adjustment
Shutter
Loosen
6
Open the bake and broil air shutter adjustments as far as possible and adjust later if necessary.
Beneath the bake and broil burner orifice hoods are LP orifice needles. To convert to L.P. tighten the orifice hoods
against the orifice needle until the hoods are snug (2-2½ turns). DO NOT OVER TIGHTEN. Check the burners for
proper flame adjustment. The burner flame should have approximately 1" blue cones. With most LP gas, small
yellow tips at the end of outer cones are normal. flames should not lift off burner ports. If lifting is observed,
gradually reduce the air shutter opening until flames are stabilized.
ORIFICE INFORMATION
IMPORTANT NOTE:
Always consult the Technical Service
literature (mini-manual) enclosed with the appliance for model
specific conversion information
JGBP85BEA Orifice Charts
BAKE BURNER
ADJUSTMENTS
BROIL BURNER
ADJUSTMENTS